INSTALLATION | ||
|
|
|
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
•Only qualified personnel should perform this installation, maintenance and troubleshooting work.
•Turn off the input power at the fuse box before working on other equipment connected to the welding system at the disconnect switch or fuse box before working on this equipment.
•Do not touch electrically hot parts.
INPUT CABLE:
For
The standard 25 foot input cable between the LN™- 23P and the power source (with a K350 Adapter Kit) consists of a
With the power source turned off, install the input cable per the following instructions:
•Connect the end of the control cable with the lugged leads to the K350 or
NOTE: If two
•Connect the input control cable polarized plug into the mating 6 pin receptacle on the rear of the con- trol section of the
•Unclip the rubber retaining strap that holds the wire enclosure cover in place and remove the cover. Push the wire drive section door latch towards the rear of the
.
For
With the power source turned off, install the input cable per the following instructions:
•The
•Connect the
•Unclip the rubber retaining strap that holds the wire enclosure cover in place, and remove the cover. Push the wire drive section door latch towards the rear of the
•Connect the
WORK CABLE AND REMOTE VOLTAGE SENSING WORK LEAD
•Connect a work cable of sufficient size and length, per the following table, between the proper output stud on the power source and the work. Be sure the connection to the work makes tight metal to metal contact.
Electrode | Work | Copper | Copper |
Cable | Cable | Electrode | Work Cable |
Length | Length | Cable Size | Size |
|
|
|
|
1/0 | 1/0 | ||
1/0 | 2/0 | ||
2/0 | 2/0 | ||
2/0 | 4/0 | ||
3/0 | 4/0 | ||
|
|
|
|
Above cable sizes are based on a maximum voltage drop of
4.3volts in the combined lengths of electrode and work cable at 350 amps.
•Connect a 12 AWG or larger rubber covered flexi- ble lead physically suitable for the installation to the voltage sensing work lead (#21) coming from the Adapter Kit. For convenience, wrap this voltage sensing lead around the work lead and tape in place. Connect it directly to the work or to the work cable connection . This lead supplies voltage to the voltmeter as well as power to the