INSTALLATION | ||
|
|
|
WIRE DRIVE ROLLS AND GUIDE TUBES
The
OPTIONAL FEATURES INSTALLATION
INNERSHIELD GUN AND CABLE
•Unclip the rubber retaining strap that holds the wire enclosure cover in place and remove the cover.
•Push the wire drive section door latch towards the rear of
•Loosen the gun locking set screw in the conductor block on the front of the gear box with a 3/16 hex Allen wrench.
•Lay the cable out straight. Insert the connector on the conductor cable thru the large grommet in the front of the wire drive section and into the brass block on the front of the gear box. Make sure it is all the way in and tighten the locking set screw with a 3/16 hex Allen wrench. Keep this connection clean and bright.
•Connect the 3 pin gun trigger connector to the lower receptacle.
•If the gun cable being used has a reduced speed switch, connect the 4 pin reduced speed switch con- nector to the upper receptacle. If the reduced speed switch is not used, install the protective cap on the upper receptacle.
•
•
•Other Power Sources: Mount the Adapter Kit to the side of the power source or some convenient location so its control cable can be connected to the power source terminal strip. Use the shock mounted mount- ing plate as a template to locate the four 5/32" diame- ter holes that must be drilled in the case side. (Use caution not to drill into or get chips into any internal components.) Mount the Adapter Kit with four of the #10
Used to connect an
•Mount the Adapter Kit to the side of the power source or some convenient location so its control cable can be connected to the power source terminal strip. See the mounting instructions form the K350
•Connect the Adapter control cable to 14 pin connector on the power source per the proper connection dia- gram.
•Connect a 12 AWG or larger rubber covered flexible lead physically suitable for the installation to the volt- age sensing work lead (#21) coming from the LN23P control cable connector. For convenience, wrap this voltage sensing lead around the work lead and tape in place. Connect it directly to the work or to the work cable connection
CAUTION