Lincoln Electric IM724 Code Requirements for Input Connections, Requirements For Rated Output

Models: IM724

1 45
Download 45 pages 42.3 Kb
Page 13
Image 13

A-6

 

INSTALLATION

 

A-6

 

 

 

 

 

INPUT CONNECTIONS

Refer to Figure A.6.

The SP-135T has a power input cable located on the rear of the machine.

GAS SOLENOID

INLET FITTING

POWER INPUT

CABLE

FIGURE A.6

CODE REQUIREMENTS FOR INPUT CONNECTIONS

WARNING

This welding machine must be connected to a power source in accordance with applicable elec- trical codes.

The United States National Electrical Code (Article 630-B, 1990 Edition) provides standards for amperage handling capability of supply conduc- tors based on duty cycle of the welding source.

If there is any question about the installation meeting applicable electrical code requirements, consult a qualified electrician.

Requirements For Rated Output

A power cord with a 15 amp, 125 volt, three prong plug (NEMA Type 5-15P) is factory installed on the SP-135T. Connect this plug to a mating grounded receptacle which is connected to a 20 amp branch cir- cuit with a nominal voltage rating of 115 to 125 volts, 60 Hertz, AC only.

The rated output with this installation is 90 amps,19 Volts, 20% duty cycle (2 minutes of every 10 minutes used for welding).

CAUTION

Do not connect the SP-135T to an input power supply with a rated voltage that is greater than 125 volts.

Do not remove the power cord ground prong.

SP-135T

Page 13
Image 13
Lincoln Electric IM724 manual Code Requirements for Input Connections, Requirements For Rated Output