A-1

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – SP-135T

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

120V/60Hz

Input Current

20 Amps - Rated Output

Duty Cycle

20% Duty Cycle

Welding Current Range

25-135 Amps

RATED OUTPUT

Amps

90

OUTPUT

Maximum-Open Circuit Voltage

29V

Volts at Rated Amperes

19

50 - 300 in/min

(1.3 - 7.6 m/min)

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

Fuse or

 

 

 

Output Mode

Input Voltage

Breaker Size1

Input Amps

Power Cord

Extension Cord

 

 

 

 

 

Three Conductor

 

 

 

 

 

#14 AWG

 

 

 

 

 

(2.1 mm2) or Larger

RATED

120V/60Hz

20 Amp

20

15 Amp, 125V,

Up to 25 Ft. (7.6 mm)

 

 

 

 

 

Three Prong Plug

Three Conductor

 

 

 

 

(NEMA Type 5-15P)

#12 AWG

 

 

 

 

 

(3.3 mm2) or Larger

 

 

 

 

 

Up to 50 Ft. (15.2 mm)

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

48 Ibs

305 mm

248 mm

419 mm

21.8 kg

 

 

 

 

1If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.

SP-135T

Page 8
Image 8
Lincoln Electric IM724 manual Installation, Technical Specifications SP-135T