Lincoln Electric IM794 Input Connections, Installation, Never lift welder with cylinder attached

Models: IM794

1 36
Download 36 pages 26.13 Kb
Page 12
Image 12
• Keep cylinder away from areas where it may be damaged.

A-5

INSTALLATION

A-5

WARNING

CYLINDER may explode if dam- aged. Keep cylinder upright and chained to support

• Keep cylinder away from areas where it may be damaged.

Never lift welder with cylinder attached.

Never allow welding electrode to touch cylinder.

Keep cylinder away from welding or other live electrical circuits.

WARNING

BUILDUP OF SHIELDING GAS may harm health or kill.

• Shut off shielding gas supply when not in use.

SEE AMERICAN NATIONAL STANDARD Z-49.1, “SAFETY IN WELDING AND CUTTING” PUB- LISHED BY THE AMERICAN WELDING SOCIETY.

1.Chain the cylinder to a wall or other stationary sup- port to prevent the cylinder from falling over. Insulate the cylinder from the work circuit and earth ground. Refer to Figure A.5.

 

FIGURE A.5

Flow Regulator

Cylinder Valve

Gas Hose •Never lift welder with cylinder attached.

2.With the cylinder securely installed, remove the cylinder cap. Stand to one side away from the out- let and open the cylinder valve very slightly for an instant. This blows away any dust or dirt which may have accumulated in the valve outlet.

WARNING

BE SURE TO KEEP YOUR FACE AWAY FROM THE VALVE OUTLET WHEN “CRACKING” THE VALVE. Never stand directly in front of or behind the flow regulator when opening the cylinder valve. Always stand to one side.

3.Attach the flow regulator to the cylinder valve and tighten the union nut securely with a wrench.

NOTE: If connecting to 100% CO2 cylinder, insert regulator adapter (provided with MIG Conversion Kit) between regulator and cylinder valve. If adapter is equipped with a plastic washer, be sure it is seat- ed for connection to the CO2 cylinder.

4.Refer to Figure A.6. Attach one end of inlet gas hose to the outlet fitting of the flow regulator and tighten the union nut securely with a wrench. Connect the other end to the machine Gas Solenoid Inlet Fitting (5/8-18 female threads — for CGA — 032 fitting). Make certain the gas hose is not kinked or twisted.

5.Reinstall case side before connecting input power.

INPUT CONNECTIONS

Refer to Figure A.6.

The machine has two input connections, the power input cable, and the Gas Solenoid Inlet Fitting. Both are located on the rear of the machine.

FIGURE A.6

GAS SOLENOID

INLET FITTING

POWER INPUT

CABLE

SP-170T

Page 12
Image 12
Lincoln Electric IM794 Input Connections, Installation, Keep cylinder away from areas where it may be damaged, FIGURE A.5