E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Engine will not go to high idle when

1.

No voltage signal from the

using auxiliary power.

 

current sensor.

 

2.

Auxiliary power load less than

 

 

100 to 150 watts.

 

3.

Faulty P.C. Board.

 

 

 

 

Engine will not crank or is hard to

1.

Battery will not hold a charge.

crank.

 

Faulty Battery.

 

2.

No or insufficient charging

 

 

current.

 

3.

Loose battery cable

 

 

connection(s).

 

 

 

 

Engine shuts down.

1.

Out of fuel.

 

2.

Low oil level.

 

 

Engine does not develop full power. 1. Fuel filter clogged.

 

2.

Air filter clogged.

 

 

 

 

Engine is hard to start.

1.

Spark plugs do not have

 

 

specified gap.

 

2.

Spark plugs are fouled.

 

 

 

 

No auxiliary power.

1.

GFCI Receptacle may have

 

 

 

tripped. Follow “GFCI Receptacle

 

 

Testing and Resetting Procedure”

 

 

in the MAINTENANCE section of

 

 

this manual.

 

2.

Open breakers may need to be

 

 

reset.

If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Authorized Field Service Facility.

3.Faulty receptacle.

4.Faulty auxiliary circuit wiring.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.