TROUBLESHOOTING | ||
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
White or Blue Smoke. | 1. | Excess engine oil. |
|
| 2. | Too low viscosity of the |
|
|
| engine oil. |
|
| 3. | Faulty injection timing. |
|
|
|
|
|
Dark Grey Smoke. | 1. | Unsuitable fuel. |
|
| 2. | Excess injection. |
|
| 3. | Faulty function of the engine. |
|
| 4. | Overloading. |
|
| 5. | Clogged air cleaner. |
|
|
|
|
|
Faulty Charging. | 1. | Loose fan belt. |
|
| 2. | Faulty wiring. |
|
| 3. | Faulty battery. |
|
| 4. | Worn out alternator brush. |
|
|
|
|
|
Starter Motor does not run. | 1. | Loose or damaged wiring. |
|
| 2. | Drained voltage from battery. |
|
| 3. | Damaged starter motor | If all recommended possible areas |
|
| (including solenoid). | of misadjustment have been |
|
|
| checked and the problem persists, |
|
|
| Contact your local Lincoln |
Engine Protection Light not com- | 1. | Broken Light Bulb. | Authorized Field Service Facility. |
ing on. | 2. | Faulty light wiring. |
|
| 3. | Faulty Engine Control Unit. |
|
|
|
|
|
No auxiliary power. | 1. | GFCI Receptacle may have |
|
|
| tripped. Follow “GFCI |
|
|
| Receptacle Testing and |
|
|
| Resetting Procedure” in the |
|
|
| MAINTENANCE section of |
|
|
| this manual. |
|
| 2. Open breakers may need to |
| |
|
| be reset. |
|
| 3. | Faulty receptacle. |
|
| 4. Faulty auxiliary circuit wiring. |
| |
|
|
|
|
|
|
|
|
CAUTION