Lincoln Electric IM927 manual Connection of Weldmark 225 to Premises Wiring

Models: IM927

1 35
Download 35 pages 28.82 Kb
Page 16
Image 16

A-9

INSTALLATION

A-9

 

 

 

Figure 1

CONNECTION OF WELDMARK 225 TO PREMISES WIRING

 

240 VOLT

240 Volt

POWER

120 VOLT

60 Hz.

COMPANY

3-Wire

120 VOLT

Service

METER

 

GROUNDED CONDUCTOR

NEUTRAL

BUS

N

LOAD

DOUBLE POLE DOUBLE THROW

SWITCH RATING TO BE THE SAME

AS OR GREATER THAN PREMISES

SERVICE OVERCURRENT

PROTECTION.

50 AMP, 120/240

VOLT PLUG240 VOLT NEMA TYPE 14-50

40AMP

240VOLT

DOUBLE

POLE

CIRCUIT

BREAKER

GND

N

PREMISES

DISCONNECT AND

SERVICE

GROUNDOVERCURRENT PROTECTION

50 AMP, 120/240 VOLT

RECEPTACLENOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE

SIZE RECOMMENDATIONS.

WARNING

Connection of WELDMARK 225 to premises wiring must be done by a licensed electrician and must comply with the National Electrical Code and all other applicable electrical codes.

WELDMARK225

Page 16
Image 16
Lincoln Electric IM927 manual Connection of Weldmark 225 to Premises Wiring