WELDMARK 225

WELDMARK 225 / LN-15 AND LN-25 ACROSS THE ARC CONNECTION DIAGRAM

WARNING

ELECTRIC SHOCK can kill

MOVING PARTS can injure

Do not operate with panels open.

Keep guards in place.

Disconnect NEGATIVE (-)Battery lead

Keep away from moving parts.

before servicing.

Only qualified personnel should install,use

Do not touch electrically live parts.

or service this equipment.

 

ENGINE

 

 

WELDER

 

 

LN-15 OR LN-25

 

 

WIRE FEEDER

WORK CLIP LEAD

TO WORK ELECTRODE

 

 

 

 

 

TO WORK

 

TO WORK

 

 

ELECTRODE CABLE

 

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT DUTY CYCLE OF APPLICATION.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR

SWITCH TO THE WIRE FEED (CV) POSITION.

A.02

M20266

F-2

DIAGRAMS

F-2

Page 31