6.4Timing chart

(1)Data Input and Printing Timing

ACK is not outputted.

T1, T2, T3

: 0.5 micro sec. MIN

T4

: 270 ns MAX

T5

: 2.3 micro sec. TYP

T6

: 500 ms MIN (On supplying power)

6.5 Data receiving control

When BUSY signal is "LOW", data from the host can be received. When it being "HIGH", data can not be received.

6.6 Buffering

4 K bytes input buffer is incorporated. Due to this large buffer, host side is released immediately.