Lincoln Electric R350 manual Electrode Voltage Sensing, Work Voltage Sensing

Models: R350

1 42
Download 42 pages 55.29 Kb
Page 15
Image 15

A-8

INSTALLATION

A-8

Electrode Voltage Sensing

 

 

The remote ELECTRODE sense lead (67) is built into the 5-pin arclink control cable (K1543-xx) and is always connected to the wire drive feed plate when a wire feeder is present. Enabling or disabling electrode voltage sensing is application specific, and automati- cally configured by the active weld mode.

Work Voltage Sensing

While most applications perform adequately by sens- ing the work voltage directly at the output stud, the use of a remote work voltage sense lead is recom- mended for optimal performance. The remote WORK sense lead (21) can be accessed through the four-pin voltage sense connector located on the control panel by using the K940 Sense Lead Kit. It must be attached to the work as close to the weld as practical, but out of the weld current path. For more information regarding the placement of remote work voltage sense leads, see the section entitled "Voltage Sensing Considerations for Multiple Arc Systems."

Negative Electrode Polarity

The POWER WAVE R350 has the ability to automati- cally sense the polarity of the sense leads. With this feature there are no set-up requirements for welding with negative electrode polarity. This feature can be disabled through the Diagnostics Utility (available at www.powerwavesoftware.com).

CAUTION

If the auto sense lead feature is disabled and the weld polarity attribute is improperly configured extremely high welding outputs may occur.

------------------------------------------------------------------------

POWER WAVE® R350

Page 15
Image 15
Lincoln Electric R350 manual Electrode Voltage Sensing, Work Voltage Sensing