TROUBLESHOOTING | ||
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Ethernet
Cannot Connect | 1. Physical connection. | 1. Verify that the correct patch cable | |
|
|
| or cross over cable is being used |
|
|
| (refer to local IT department for |
|
|
| assistance). |
|
|
| 1a. Verify the cables are fully insert- |
|
|
| ed into the bulk head connector. |
|
|
| 1b. The LED under the PC board |
|
|
| ethernet connector will be lit |
|
|
| when the machine is connected |
|
|
| to another network device. |
|
|
|
|
|
| 2. IP address information. | 2. Use the appropriate PC utility to |
|
|
| verify the correct IP address infor- |
|
|
| mation has been entered. |
|
|
| 2a. Verify no duplicate the IP |
|
|
| addresses exist on the network. |
|
|
|
|
|
| 3. Ethernet Speed | 3. Verify that the network device |
|
|
| connected to the Power Wave is |
|
|
| either a |
|
|
| |
|
|
|
|
Connection Drops while welding | 1. Cable Location | 1. Verify Network cable is not locat- | |
|
|
| ed next to current carrying con- |
|
|
| ductors. This would include input |
|
|
| power cables and welding output |
|
|
| cables. |
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.