A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS – SP-100T

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

115V/60Hz

Input Current

20 Amps - Rated Output

15 Amps - CSA Rated output

Duty Cycle

20% Duty Cycle

20% Duty Cycle – CSA Rated Output

Welding Current Range

Rated DC Output: 30 - 100 amps

RATED OUTPUT

Current 88Amps 62Amps

OUTPUT

Maximum Open Circuit Voltage

32

Voltage

18V

20V

Wire Speed Range

50 - 300 in/min

(1.3 - 7.6 m/min)

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

Fuse or

 

 

 

 

 

Output Mode

Input Voltage

Breaker Size

Input Amps

Power Cord

 

Extension Cord

 

 

 

 

 

 

 

 

 

RATED

115V/60Hz

20 Amp

20

15 Amp, 125V,

 

Three Conductor

 

 

#14 AWG

 

 

 

 

 

Three Prong Plug

 

 

 

 

 

 

 

(2.1 mm2) or Larger

 

 

 

 

 

(NEMA Type 5-15P)

 

 

 

 

 

 

 

Up to 25 Ft. (7.6 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSA

115V/60Hz

15 Amp

15

15 Amp, 125V,

 

Three Conductor

 

 

 

 

 

Three Prong Plug

 

#12 AWG

 

 

 

 

 

(NEMA Type 5-15P)

 

(3.3mm2) or Larger

 

 

 

 

 

 

 

Up to 50 Ft. (15.2 mm)

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

Height

Width

Depth

Weight

 

12.0 in

9.75 in

16.5 in

47 Ibs

 

305 mm

248 mm

419 mm

21.4 kg

 

 

 

 

 

 

 

 

SP-100T

Page 8
Image 8
Lincoln Electric manual Installation, Technical Specifications SP-100T