TROUBLESHOOTING & REPAIR
NOTE: Proper capacitor polarity must be noted when
attaching the capacitor to the Switch Board assembly.
6. Install the new Capacitor and tighten the two bolts
to a torque of 55 inch-pounds (6 Nm). Hand tight-
en first, then tighten the bolts in increments of 10
inch-pounds, alternating between the two. See
Figure F.27.
7. Tighten the set screw of the clamping ring
8. Perform the Test After Repair of Switch Boards
and/or Capacitors.
F-54 F-54
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
FIGURE F.29 -- COMPLETE SWITCH BOARD ASSEMBLYREADY FOR INSTALLATION
CAPACITOR REMOVAL AND REPLACEMENT (cont.)