V300-PRO
TROUBLESHOOTING & REPAIR
TEST PROCEDURE
1. Locate the Output Terminals on front panel.
2. Remove any cables from Output Terminals.
3. Test for more than 200 ohms resistance between
positive and negative Output Terminals: positive
meter lead to the positive terminal, negative meter
lead to the negative terminal.
NOTE: Polarity of test leads is important.
a. If reading is more than 200 ohms, Output
Diodes are OK.
b. If reading is less than 100 ohms, one or more
Output Diode is shorted. Test all Output Diodes
(D-1 thru D-12) or diode modules individually.
NOTE: On codes prior to 10200 the diodes should
also be tested individually to check for “Open”
diodes. An open diode may cause an imbalance
condition when output is activated. Be sure to per-
form the Input Filter Capicitor Discharge
Procedure as detailed in this section.
F-32 F-32
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC

OUTPUT DIODE TEST (cont.)

-+
- PROBE
+ PROBE
LINCOLN
FIGURE F.10 — TESTING OUTPUT DIODES.