Linear AE1000Plus 57#LINE 1#LINE 2#, 64#TIME#, 67#RELAY#, 65#DEVICE#TYPE#CHANNEL#, Set Talk Time

Models: AE1000Plus

1 12
Download 12 pages 25.92 Kb
Page 9
Image 9
Function 57: Welcome Display Text

8 Local Programming Functions (Continued)

Function 57: Welcome Display Text

The welcome text displayed by the Controller can be modifi ed using this function. Refer to the keypad alphanumeric key fi gure shown on Page 4 for keypad details.

EDIT WELCOME DISPLAY TEXT

FCN 57

57#LINE 1#LINE 2#

LINE 1 = TEXT FOR FIRST LINE OF THE DISPLAY

LINE 2 = TEXT FOR THE SECOND LINE OF THE DISPLAY

Function 64: Set Talk Time

(AE1000Plus and AE200Plus Only)

The length of time allowed for the Visitor to talk with the Resident can be adjusted using this function (the default time is 60 seconds). The Talk Time can be extended during the call by the Resident by pressing the pound (#) telephone key.

Function 65: Configure Remote Devices

Remote devices can be confi gured for type, device number, and the relay that the device will activate. Use this function to confi gure remote devices.

NOTE: AM3Plus panels will not accept Type 7 devices. Do not change the device type from “Remote Keypad” on Device #1 to any other device type. Doing so will result in loss of local programming control, and will require clearing of the panel. Clearing of the panel will result in the loss of any existing programming information.

SET TALK TIME

FCN 64

64#TIME#

TIME = TALK TIME IN SECONDS

CONFIGURE REMOTE DEVICES

FCN 65

65#DEVICE#TYPE#CHANNEL#

DEVICE = DEVICE NUMBER (AccessBase 1-9, AxNet 1-4, 7, 8 or 9)

TYPE = DEVICE TYPE NUMBER (SEE BELOW) CHANNEL = 1-4 FOR RELAY A-D; 5 FOR BUTTONS

TYPE 0 = NONE

TYPE 1 = REMOTE KEYPAD

TYPE 2 = RADIO

TYPE 3 = WIEGAND26 CARD READER

TYPE 4 = WIEGAND30 CARD READER

TYPE 5 = WIEGAND31 CARD READER

TYPE 7 = TELEPHONE INTERFACE (ALWAYS DV7)

Function 67: Postal Key Door

The relay channel that the postal lock key will activate can be programmed using this function (the default is Channel A). The postal lock can be programmed to activate Relay Channel A, B, C, or D.

Function 99: Exit Programming Mode

Use this function to exit programming mode.

POSTAL KEY DOOR

FCN 67

67#RELAY#

RELAY = 1 FOR RELAY CHANNEL A 2 FOR RELAY CHANNEL B 3 FOR RELAY CHANNEL C 4 FOR RELAY CHANNEL D

EXIT PROGRAMMING MODE

FCN 99

99#

7

Page 9
Image 9