8 Local Programming Functions (Continued)
Function 44: Set Button Schedule
Access relays can be programmed to activate from a specifi c button on
SET BUTTON SCHEDULEFCN 44
44#RLY-A#RLY-B#RLY-C#RLY-D#
RLY A = RELAY A BUTTON | 0 | = NONE | 4 | = TOP | |
5 | = TOP LEFT | ||||
RLY B = RELAY B BUTTON | 1 | = ANY | 6 | = TOP RIGHT | |
RLY C = RELAY C BUTTON | 2 | = LEFT | |||
7 | = BOTTOM LEFT | ||||
RLY D = RELAY D BUTTON | 3 | = RIGHT | |||
8 | = BOTTOM RIGHT |
Function 52: Configure Onboard Relays
Access relays can be programmed to activate for different lengths of time; be set for pulse, toggle, or latch; and set to stay latched during a selected time zone. Use this function to confi gure each relay.
CONFIGURE ONBOARD RELAYS | FCN 52 |
CH = 1 FOR RLY A; 2 FOR RLY B; 3 FOR RLY C; 4 FOR RLY D TIMING = 1 FOR ACTIVATION TIME
2 FOR 1/4 SECOND PULSE ACTIVATION
3 FOR TOGGLE
4 FOR LATCH
OPERATION = 1 FOR CONTROL; 4 FOR OBSTACLE
TZ1 = TIME ZONE NUMBER FOR RELAY HELD ON (# TO SKIP) TZ2 = TIME ZONE NUMBER FOR RELAY HELD ON (# TO SKIP) (SKIP TZ1 & TZ2 FOR OBSTACLE TRANSMITTERS)
TIME = ACTIVE TIME IN SECONDS (ONLY FOR MODE 1)
Function 55: Enter Obstacle Transmitters
One or two Model MGT Gate Safety Edge Transmitters can be programmed into the Controller. Each obstacle transmitter can be programmed to trigger Relay Channel C or Relay Channel D. Use this function to enter obstacle transmitters into memory.
Function 56: Delete Obstacle Transmitters
Obstacle transmitters can be deleted from the Controller using this function. The function will remove one transmitter at a time.
ENTER OBSTACLE TRANSMITTERS | FCN 55 |
55#RLY#FC#ID#
RLY = 1 FOR RELAY C; 2 FOR RELAY D FC = FACILITY CODE
ID = TRANSMITTER ID
DELETE OBSTACLE TRANSMITTERS | FCN 56 |
56#TX NUM#
TX NUM = 1 FOR RELAY C TRANSMITTER 2 FOR RELAY D TRANSMITTER
6