Link electronic Door phone manual Max. time sec between button presses range, 15 ∗

Models: Door phone

1 18
Download 18 pages 36.48 Kb
Page 13
Image 13

d– maximum time in minutes for which a call may last. This time can be extended during a call by dialling Prolong Call digit from telephone (or #). Time setting is per table.

 

 

 

 

 

 

Parameter

Value

Description

Default

Exam.1

Exam.2

 

 

 

 

 

 

53

w

time between button

2

2

2

presses

 

 

 

 

 

 

 

 

w – max. time [sec] between button presses [range 1-9]

 

 

time

choice

[min]

 

0,5

0

1 - 9

1 - 9

15

30#

-relay closing – if time between two next presses is bigger than w time, the code is not evaluated correctly.

-dialling – if the button pressed is the first password number for switch closing, so the choice is delayed by this w time.

 

 

 

 

 

 

Parameter

Value

Description

Default

Exam.1

Exam.2

54

z

On hook time before new

2

2

2

call

 

 

 

 

 

 

 

 

 

 

 

z– time [sec] for which the unit will hang up, before repeat dialling (button pressing during call or dialling, busy tone detection) [range 1-5]

 

 

 

 

 

 

Parameter

Value

Description

Default

Exam.1

Exam.2

 

 

 

 

 

 

55

z

Call start time

1

1

1

 

 

 

 

 

 

z– time [sec] after unit goes on hook before dialling [range 1-5]. This time is different for each PBX, but most PBXs usually manage to process dialling up to 2 seconds after line on hook.

 

 

 

 

 

 

Parameter

Value

Description

Default

Exam.1

Exam.2

 

 

 

 

 

 

56

h

Number of rings before

12

12

12

hanging up or group mode

 

 

switching

 

 

 

 

 

 

 

 

 

h – specifies the amount of time spent ringing before the unit hangs up and tries the next number.

 

 

 

 

 

 

Parameter

Value

Description

Default

Exam.1

Exam.2

 

 

 

 

 

 

57

t

DTMF tone duration (ms)

5

5

5

(100ms)

(100ms)

(100ms)

 

 

 

58

m

Space duration between

5

5

5

DTMF tones (ms)

(100ms)

(100ms)

(100ms)

 

 

59

f

Recall duration (ms)

1

1

1

(100ms)

(100ms)

(100ms)

 

 

 

50

p

Pause duration (ms)

8

8

8

(800ms)

(800ms)

(800ms)

 

 

 

 

 

 

 

 

 

t– DTMF tone duration is determined by the formula: (entered number + 5) x 10 = tone duration [ms]

[range 1-0 i.e. 60-150ms]

mSpace duration between DTMF tones is determined by the formula:

(entered number + 5) x 10 = gap duration [ms]

[range 1-0 i.e. 60-150ms]

f– Recall duration is determined by the formula: entered number x 100 = Recall duration [ms]

[range 1-6 i.e. 100-600ms]

p– Pause duration is determined by the formula: entered number x 100 = pause duration [ms]

[range 5-0 i.e. 500-1000ms]