Lochinvar EB-EWU-02 Relief Valve, Vent System Options, Avoid contact with hot discharge water

Models: 000 - 300 150 EB-EWU-02

1 8
Download 8 pages 58.75 Kb
Page 3
Image 3

RELIEF VALVE

 

￿ WARNING

 

 

 

This appliance is supplied with a relief valve(s) sized in accordance with ASME Boiler and Pressure Vessel Code, Section IV ("Heating Boilers"). The relief valve(s) is installed in the vertical position and mounted in the hot water outlet. No valve is to be placed between the relief valve, and the appliance. To prevent water damage, the discharge from the relief valve shall be piped to a suitable floor drain for disposal when relief occurs. No reducing couplings or other restrictions shall be installed in the discharge line. The discharge line shall allow complete drainage of the valve and line. Relief valves should be manually operated at least once a year.

￿CAUTION

Avoid contact with hot discharge water.

VENT SYSTEM OPTIONS

This appliance has five venting options. They are:

1.Conventional Negative Draft Venting Conventional negative draft venting with vertical termination.

2.E+ with a Vertical Conventional Vent

E+Vent with a vertical conventional vent for flue products and a combustion air pipe from either the sidewall or roof top.

3.Direct Venting with Sidewall Terminations Direct vent with sidewall terminations for flue products and combustion air.

4.Direct Venting with Vertical Terminations Direct vent with vertical through-roof terminations for flue products and combustion air.

Using other vent or air intake materials, failure to properly seal all seams and joints or failure to follow vent pipe manufacturer's instructions can result in personal injury, death or property damage. Mixing of venting materials will void the warranty and certification of the appliance.

IMPORTANT:

Examine the venting system at least once a year. Check all joints and vent pipe connections for tightness. Also check for corrosion or deterioration. Immediately correct any problems observed in the venting system.

COMBUSTION AND VENTILATION AIR

REQUIREMENTS FOR

CONVENTIONALLY VENTED

APPLIANCES

Provisions for combustion and ventilation air must be in accordance with Section 5.3, Air for Combustion and Ventilation, of the latest edition of the National Fuel Gas Code, ANSI Z223.1, in Canada, the latest edition of CGA Standard B149 Installation Code for Gas Burning Appliances and Equipment, or applicable provisions of the local building codes.

￿CAUTION

Under no circumstances should the equipment room ever be under a negative pressure. Particular care should be taken where exhaust fans, attic fans, clothes dryers, compressors, air handling units, etc., may take away air from the unit.

5.Outdoor Installation

Outdoor installation consists of the installation of a special vent cap / top assembly, gas valve cover, deflectors, and a weatherproof junction box.

All appliances are shipped from the factory equipped for conventional negative draft venting. All other optional vent systems require the installation of specific vent kits and venting materials. See the Installation and Service Manual for a detailed explanation of the installation requirements for each venting system, components used and part numbers of vent kits for each model.

E+ Vent and Direct Vent Units

These optional venting systems use two pipes, one pipe to exhaust flue products and one pipe to supply combustion air directly to the appliance. The optional vent systems have specific material and installation requirements. The combustion air pipe for the optional vent systems may terminate horizontally with a sidewall air inlet or vertically with a rooftop air inlet, based on the venting system installed. A detailed explanation of the installation requirements for each venting system, components used and part numbers of vent kits for each model is included in the Installation and Service Manual. No additional combustion air openings are required for the mechanical room when the optional two pipe venting systems are properly installed.

3

Page 3
Image 3
Lochinvar EB-EWU-02, 150 Relief Valve, Vent System Options, Avoid contact with hot discharge water, Outdoor Installation

000 - 300, 150, EB-EWU-02 specifications

Lochinvar has built a strong reputation in the field of advanced heating technology, and the Lochinvar 000 - 300,EB-EWU-02,150 unit epitomizes this legacy. This high-efficiency water heater is designed for commercial applications, delivering reliable hot water supply with exceptional performance while prioritizing energy savings.

One of the main features of the Lochinvar 000 - 300 is its impressive thermal efficiency. With a rating that exceeds industry standards, it ensures maximum heat transfer with minimal energy loss. The unit operates at a high combustion efficiency, allowing it to deliver significant cost savings over its lifespan. This efficiency is attributed to its innovative heat exchanger design, which optimizes the transfer of heat, ensuring rapid recovery rates.

Technologically, the Lochinvar 000 - 300 incorporates advanced control systems that enhance its operational capabilities. It features a user-friendly interface that allows for precise temperature adjustments and monitoring, ensuring that hot water is available whenever it is needed. Additionally, this unit is equipped with advanced safety systems, including flame monitoring and a comprehensive diagnostic suite that provides real-time performance data, enhancing reliability and reducing maintenance needs.

The Lochinvar 000 - 300 is crafted from high-quality materials that ensure durability and resilience, even in demanding environments. Its robust construction not only allows it to withstand the rigors of commercial use but also extends its operational life, making it a cost-effective solution in the long run.

In terms of installation, the Lochinvar 000 - 300 is designed for flexibility. It can be easily integrated into existing systems, accommodating various configurations while minimizing the need for extensive modifications. Its compact design allows for installation in tight spaces without compromising performance.

Additional characteristics include a powerful pump for efficient circulation and a range of compatibility with different fuels, including natural gas and propane, making it a versatile choice for many applications.

In conclusion, the Lochinvar 000 - 300,EB-EWU-02,150 stands out with its exceptional efficiency, advanced technology, and reliable performance, making it an ideal choice for commercial water heating needs. Its focus on energy savings and user convenience positions it as a leader in the industry, ensuring that businesses can deliver hot water effectively while controlling operation costs.