10 Faults, causes and rectification

SL-PS Installation & Operation Manual

10 Faults, causes and rectification

Pump doesn’t run when power is switched on :

Check solar control unit for correct settings and tight wire connections.

Check fuses.

Check pump voltage, refer to the pump rating plate for requirements.

Motor blocked:

Close shut-off instruments upstream and downstream of pump at high liquid temperatures and system pressures. Allow pump to cool first.

Fully unscrew bleed screw and check ease of movement of pump rotor by turning the slotted shaft end with a screwdriver; use force to turn if necessary.

Pump Noise:

In the event of cavitation caused by insufficient inlet pressure, increase primary system pressure within allowable range.

Check speed setting.

If the fault cannot be rectified, please contact your nearest

Lochinvar/TiSUN customer service representative.