LANDSCAPE-STYLE DVS AND DVL

FIREPLACE FRAMING SPECIFICATIONS

Please refer to the Owner’s Manual for all installation information. Owner’s Manuals can be downloaded from the Lopi website under the specific product -- www.lopistoves.com.

17 1 DVS - DIRECT VENT SMALL

CORNER INSTALLATIONS

36”

When using an elbow off the top of the unit the fireplace, allow for a 2” clearance above the vent and 1” to the sides and bottom.

13”

13 5/8”

19 3/8”

35”

19 5/8”

37 1/4”

Hearth Requirements:

When venting to the rear, allow a min.

8 5/8” gap centered behind the fireplace for the vent and wall thimble.

46 3/4”

14

3/8”

 

37”

3/4”

65

 

Fireplace includes 1/2” stand offs

A non-combustible hearth is required. Non-combustible hearth must be a minimum of 29 7/8” to 33 1/8” wide (depending on face) x 12” deep and a minimum of 1 1/4” thick.

2 DVL - DIRECT VENT LARGE

46 3/4”

 

20 1/2”

44

1/4”

Hearth Requirements:

47 3/4”

The fireplace enclosure must not be less than 54 3/4” above the base of the fireplace

When using an elbow off the top of the unit the fireplace, allow for a 3” clearance above the vent and 1” to the sides and bottom.

When venting to the rear, allow a min. 10” gap centered behind the fireplace for the vent and wall thimble.

CORNER INSTALLATIONS

14 3/4”

13 3/4

19 3/8”

1” Stand offs

47

5/8”

44

1/4”

 

 

 

 

Minimum 1” clearance to fireplace enclosure

A non-combustible hearth is required. Non-combustible hearth must be a minimum of 32 3/4” to 37 5/8” wide (depending on face) x 12” deep and a minimum of 3/4” thick. When fireplace is raised a minimum of 3”off of the floor surface, no hearth is required.

Page 18
Image 18
Lopi 21 TRV manual LANDSCAPE-STYLE DVS and DVL Fireplace Framing Specifications, Corner Installations