CF353C, CF354C, CF503C, CF504C, CF653C, CF654C - -

STANDING PILOT

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot, which must be lighted by hand. When lighting the pilot, follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the information on the safety label.

2.Set thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.Remove cabinet door.

5.Push in gas control lever slightly and slide right to “OFF”.

MAX. (HIGH)

PRESSURE REGULATOR

Gas Control

Lever

 

 

(MANIFOLD)OUTLET

PRESSUREAPT

NOTE: Lever

cannot be

 

 

moved to “OFF” unless it is pushed in slightly. Do not force.

STEP PRESSURE REGULATOR

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the information on the safety label. If you don’t smell gas, go to the next step.

7.Locate red piezo ignitor button. Locate pilot. (Follow

metal pilot tube from gas control).

PILOTBURNER

The pilot is located on the side of the burner

8. Slide gas control lever left to “SET” and hold. Immediately begin a series of pushing and releasing the red piezo ignitor button, while observing the pilot. Continue to spark until pilot is lit. Continue to hold the gas control lever to “SET” for about one (1) minute after the pilot is lit. Release the gas control lever and it will return to “PILOT”. Pilot should remain lit. If pilot goes out, repeat steps 5 thru 8.

If gas control lever does not return to “PILOT” when released, STOP and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, slide the gas control lever to “OFF” and call your service technician or gas supplier.

9. Slide gas control lever left

to “ON”.

10.Replace cabinet.

11.Turn on all electric to the appliance.

12.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.

Turn thermostat to lowest setting.

4.

Push in gas control lever slightly and slide right

 

to “OFF”. Do not force.

2.

Turn off all electric power to the appliance if service is

 

5.

Replace cabinet door.

 

to be performed.

 

 

 

3.

Remove cabinet door.

 

 

Page 10

Page 10
Image 10
Louisville Tin and Stove CF504R Standing Pilot For Your Safety Read Before Lighting, Lighting Instructions, Pilotburner

CF354C-R, CF504R, CF654C-R specifications

The Louisville Tin and Stove CF654C-R, CF504R, and CF354C-R are three distinctive models designed to provide efficient heating solutions tailored for various spaces and specific needs. Known for their stylish design and practical functionality, these units stand as a testament to craftsmanship in modern heating technology.

One of the main features of these models is their robust construction. Crafted from durable materials, they are designed to withstand the rigors of daily use while providing reliable heat. The units showcase a combination of classic aesthetics and modern functionality, allowing them to fit seamlessly in any home environment, be it traditional or contemporary.

The CF654C-R model stands out with its higher heating capacity, making it ideal for larger rooms or spaces that require significant warmth. It uses innovative heat distribution technology that ensures even warmth throughout the area, eliminating cold spots and enhancing comfort. The integrated thermostat allows users to maintain optimal temperatures effortlessly, further emphasizing energy efficiency.

The CF504R model, while slightly smaller, does not compromise on performance. It offers a perfect solution for medium-sized spaces, featuring a user-friendly interface that makes it easy to adjust settings to suit individual preferences. Advanced combustion technology maximizes fuel efficiency, resulting in lower energy bills while still delivering the heating power you expect.

The CF354C-R is tailored for smaller areas, making it the perfect choice for cozy rooms or as an additional heat source in larger homes. Despite its compact size, it is engineered with a high thermal efficiency rating, ensuring that it uses minimal fuel to produce significant heat. Its minimalist design fits easily into smaller spaces without occupying much room, making it a versatile addition to any home.

Each model integrates modern safety features, including flame failure safety devices and protective screens, ensuring peace of mind for users. Additionally, all three models are designed to accommodate a variety of fuel types, allowing homeowners to choose based on convenience and availability.

In summary, the Louisville Tin and Stove CF654C-R, CF504R, and CF354C-R are versatile heating solutions that cater to different needs, with a focus on durability, efficiency, and user-friendly operation. With their unique features and technologies, they remain a popular choice for anyone looking to enhance their home’s heating system.