INSTALLATION INSTRUCTIONS
WARNING: Use only Louisville Tin & Stove Company factory supplied parts and kits. Failure to do so could result in loss of life, personal injury, property damage, or unsatisfactory performance.
|
|
| CONTENTS OF KIT |
|
|
1 only | P/N 72532 | 2”x3” Steel Coupling | 1 only | P/N 41520 | Center Bracket |
1 only | P/N 72575 | 2”x5’ Black Flocked Tube | 8 only | P/N 72593 | 2” Hose Clamps |
1 only | P/N 72612 | 2”x6’ Black Flex Tubing | 1 only | P/N 72578 | 2”x3” Black Silicone |
2 only | P/N 41515 | Support Brackets |
| Wrapped Coupling |
STEP 1 - LOCATE VENT OPENING
a)Select location on outside wall that vent will exit through.
b)Check outside for proper clearances around vent cap. See installation instructions.
c)Mark and cut
d)Measure wall thickness. Mark and cut off both intake and exhaust pipes to 1/2” beyond outside wall.
e)Secure collection box to wall. Wall anchors, not provided, may be required.
STEP 2 - INSTALL HEATER
a)Select location on wall where heater will be installed.
b)Using wall template supplied with heater, mark location for trim kit wall brackets.
c)Attach brackets to wall (wall anchors, not provided may be required) and back of heater. Using screws provided on back of heater.
d)Slide heater into position and secure brackets togehter. This should position back of heater 5” off wall.
e)Select direction vent will exit trim kit, left, right, or straight up.
f)Before installing trim kit remove knockout on this side.
STEP 3 - INSTALL VENT
a)Remove and discard P/N 72611 2”x24” black flex tubing from air inlet. (Save hose clamp).
b)Attach P/N 72612 2”x6’ black flex tubing to air inlet. Secure with P/N 72593 2” hose clamp.
c)Slide P/N 72575 2”x5’ flocked tube through trim kit opening (knockout) and attach to P/N 72610 orange silicone 90- elbow supplied with heater. Secure with 2” hose clamp.
d)Attach P/N 41515 support brackets to wall. Wall anchors, not provided, may be required. Postion support brackets within 8” from side of trim kit and end of pipe. Secure flex tubing and flocked tube to brackets using 2” hose clamps.
e)Attach P/N 41520 center bracket
f)Connect flex air intake tube and flocked exhaust tube to collection box.
g)Complete gas connection and attach trim kit to brackets.
h)Follow lighting instructions.
SPECIAL NOTES
a)You may use up to three
b)To connect two vent kits together use P/N 72532 2”x3” steel coupling. Secure with 2” hose clamps.
c)If you are using one, two, or three kits, after installation is complete you will discard 2 P/N 72593 hose clamps and one P/N 72532 steel coupling.
d)If you need to make a 90- offset you will need to order P/N
e)If complete vent extension is horizontal, pipes may be sloped down slightly to allow any condensate to
drain through the exhaust pipe to the outside. DO NOT ALLOW TO DRAIN ONTO WALKWAY. If any part of vent extension is vertical or local codes do not allow draining of condensate to outside you must add P/N
f)For cosmetic purposes, the addition of the
P/N 72612 2”x6’ Black Flex Tubing
P/N 72532
Use only if connecting
flex tubing of 2 or
more ktis
P/N 72578 2”x3” P/N 41515
Black Silicone Support
Wrapped Coupling Brackets (2)
P/N 41520
Center Bracket
P/N 72575 2”x5’
Black Flocked Tube
P/N 72593
2” Hose Clamps
Page 14