VENT TERMINAL CLEARANCES

Vent Terminal Air Supply Inlet Area where terminal is not permitted

VENT TERMINAL CLEARANCES

REFERENCE LETTER TO

 

CANADIAN

DRAWING

 

INSTALLATIONS¹

A = Clearance above grade,

12

Inches (30 cm)

veranda, porch, deck, or

 

 

balcony

 

 

B = Clearance to window or door

12

Inches (30 cm)

that may be opened

 

 

C = Clearance to permanently

12

Inches (30 cm)

closed window

 

 

D = Vertical clearance to

18

Inches (46 cm)

ventilated soffit located above

 

 

the terminal within a horizontal

 

 

distance of 2 Feet (61 cm) from

 

 

the center line of the terminal

 

 

E = Clearance to unventilated

18

Inches (46 cm)

soffit

 

 

F = Clearance to outside corner

12

Inches (30 cm)

G = Clearance to inside corner

12

Inches (30 cm)

H = Clearance to each side of

3 Feet (91 cm) within a hei

center line extended above

15

Feet (4.5m) above the

meter/ regulator assembly

meter/regulator assembly

I = Clearance to service regulator

3 Feet (91 cm)

vent outlet

 

 

 

 

 

J = Clearance to nonmechanical

12

Inches (30 cm)

air supply inlet to building or the

 

 

combustion air inlet to any other

 

 

appliance

 

 

K = Clearance to a mechanical

6 Feet (1.83 m)

air supply inlet

 

 

L = Clearance above paved

7 Feet (2.13m) A vent shal

sidewalk or paved driveway

not terminate directly abo

located on public property

a sidewalk or paved drive

 

h

 

 

 