Louisville Tin and Stove VC351A Table Of Contents, Read Carefully Before Installing Unit, Type

Models: VC352A VC202A VC502A VC701A VCR501A VC201A VC702A VCR352A VCR702A VC351A VCR351A VCR502A VC501A VCR701A

1 17
Download 17 pages 14.84 Kb
Page 2
Image 2
TABLE OF CONTENTS

TABLE OF CONTENTS

SPECIFICATIONS……………………….

2

INTRODUCTION………………………..

3

VENTING………………………………...

3 ,4

GASSUPPLY…………………………….

5

LOCATION & SPECIAL PRECAUTIONS

5

COMBUSTION & VENTILATION AIR....

6

CLEARANCES…………………………..

7

DRAFTDIVERTER……………………..

7

DOORKNOB……………………………

7

PILOT ADJUSTMENT………………….

8

RADIANTS & GLASS PANELS……….. 8

BURNER ORIFICE & ORIFICE CHART.......... 8

PROPER BURNER FLAME.............…………. 9

MAINTENANCE…………………………....... 9

LIGHTING INSTRUCTIONS……………........ 10

TROUBLE SHOOTING CHART………… 11,12

BLOWERINSTRUCTIONS……………… 13

PARTS DRAWING……………………….. 14

PARTSPRICELIST………………………. 15

WARRANTY……………………………… 17

READ CAREFULLY BEFORE INSTALLING UNIT

These installation instructions are a general guide and do not supersede applicable local codes and ordinances. Before planning or making the installation be sure it complies with all phases of the local heating code. (Or, in the absence of local codes, with the latest edition of National Fuel Gas Code, ANSI.Z223.1, or CAN1-B149).

The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the latest edition of National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code CSA-C22.1.

All of the ANSI and NFPA standards referred to in these installation instructions are the ones that were applicable at the time the design of this appliance was certified. The ANSI standards are available from the American Gas Association, 1515 Wilson Blvd., Arlington, VA. 22209.

The NFPA standards are available from the national Fire Protection Association, 60 Batterymarch Street, Boston, Massachusetts 02110.

Canadian standards are available from International Approval Services, 178 Rexdale Boulevard, Etobicoke, Ontario, Canada M9W 1R3.

The design of this appliance was certified to comply with ANSI Z21.11.1 vented room heaters and CAN1-2.1-M86.

Installer must leave these instructions with the consumer, have them complete, and return the warranty card.

ROOM HEATER SPECIFICATIONS

Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model Number is correct and that the room heater is equipped for the type gas you intend to use.

SPECIFICATIONS

TYPE

 

 

CONTROL

 

 

 

GAS

 

 

 

 

 

 

 

 

 

 

 

 

MODEL NUMBERS

 

 

 

 

 

 

 

 

 

 

 

CLOSED FRONT

THERMOSTAT BULB

 

NATURAL

 

 

VC201A

 

VC351A

VC501A

 

 

VC701A

CLOSED FRONT

THERMOSTAT BULB

 

L.P.

 

 

VC202A

 

VC352A

VC502A

 

 

VC702A

RADIANT FRONT

THERMOSTAT BULB

 

NATURAL

 

 

N/A

 

VCR351A

VCR501A

 

 

VCR701A

RADIANT FRONT

THERMOSTAT BULB

 

L.P.

 

 

N/A

 

VCR352A

VCR502A

 

 

VCR702A

HEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20”

 

 

26”

 

 

26”

 

 

30”

WIDTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24”

 

 

30”

 

 

30”

 

 

36”

DEPTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15-1/4”

 

 

15-1/4

 

 

19-1/4”

 

 

19-1/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT (BTU/HR.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20,000

 

 

35,000

 

 

50,000

 

 

 

 

70,000

 

 

 

 

 

GAS INLET/OUTLET SIZE

 

 

 

 

 

 

 

 

 

1/2X3/8”

 

 

1/2X3/8”

 

1/2X3/8”

 

 

1/2X3/8”

VENT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3”

 

 

4”

 

 

4”

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CENTER OF VENT TO FLOOR

 

 

 

 

 

 

 

 

 

16-1/2”

 

 

21-1/2”

 

21-1/2”

 

 

25-1/2”

NUMBER OF RADIANTS (“VCR” SERIES)

 

 

 

 

 

 

 

 

 

N/A

5

 

 

 

 

 

5

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

NUMBER OF RADIANT GLASS (“VCR” SERIES)

 

 

N/A

2

 

 

 

 

 

2

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROX. SHIPPING WEIGHT (“VC” SERIES)

 

 

 

 

 

 

 

 

 

55 LBS.

 

84 LBS.

 

112 LBS.

 

 

138 LBS.

APPROX. SHIPPING WEIGHT (“VCR” SERIES)

 

 

 

 

 

 

 

 

 

N/A

 

96 LBS.

 

124 LBS.

 

 

150 LBS.

*OPTIONAL BLOWER MODEL

 

 

 

 

 

 

 

 

 

N/A

 

CHB-3

 

CHB-3

 

 

CHB-3

*Blowers also available factory mounted on 50M Btu units. All 70M Btu units come with blower mounted only.

Page 2

Page 2
Image 2
Louisville Tin and Stove VC351A Table Of Contents, Read Carefully Before Installing Unit, Room Heater Specifications, Type