Louisville Tin and Stove VC702A Draft Diverter, Door Knob, 20/35, CLEARANCES - VC20, VC35, VCR35

Models: VC352A VC202A VC502A VC701A VCR501A VC201A VC702A VCR352A VCR702A VC351A VCR351A VCR502A VC501A VCR701A

1 17
Download 17 pages 14.84 Kb
Page 7
Image 7
DRAFT DIVERTER

DRAFT DIVERTER

The draft diverter must be installed in the same atmospheric pressure zone as the combustion air supply for the main burner.

DOOR KNOB

Remove from the inside of the casing door and assemble to the outside of the door. VC201 and VC202 have finger holes in the door in lieu of knob.

 

Ceiling

 

34 IN.

18 IN.

 

45.72 CM

 

86.36 CM

 

Projection

Wall

 

22 IN.

55.88 CM

 

6 IN.

 

 

15.2 CM

 

20/35

13 IN.

 

 

33 CM

 

Floor

CLEARANCES - VC20, VC35, VCR35

 

Ceiling

 

31 IN.

18 IN.

 

45.72 CM

 

78.7 CM

 

Projection

 

 

 

 

19 IN.

Wall

 

48.3 CM

 

 

6 IN.

15.2 CM

50/70 14 IN. 35.6 CM

Floor

CLEARANCES - VC50 & VC70,

VCR50 & VCR70

CLEARANCES

If the area where the appliance is to be installed contains carpeting, tile, or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate (stoveboard), a wood panel, or other non-combustible materials. The use of ceramic or quarry tile is acceptable and provides an appealing surface that is easily cleaned. This material is to extend 2 inches from each side and 12 inches from the front. It is advisable to extend this to the wall behind the appliance.

Clearances to combustibles are as follows:

From jacket to adjacent side walls, 2” on the 20/35, and 6” on the 50/70. Maintain adequate clearance on right side for accessibility.

From rear surface vertical vent pipe to rear walls – 6”.

From rear of unit to rear wall, 13” on 20/35, and 14” on the 50/70.

From top of heater to ceiling, 34” on the 20/35, and 31” on the 50/70.

From top of heater to any overhanging projections such as a mantle or window sill is 22” on the 20/35, and 19 inches on the 50/70 models, with a maximum horizontal extension of 18 inches.

The clearances around the air opening into the combustion chamber must be maintained, and the burner must be kept clean.

Do not permit dust or dirt to accumulate here. The other clearances previously mentioned must be maintained.