CHB-3 BLOWER INSTALLATION

CHB-3 BLOWER INSTALLATION

STEP 1. Run black wire and white wire that comes from bottom of junction box down through the heat shield. See Figure A. STEP 2. Insert junction box into opening in back of heater. Attach using four #8x1/2” black screws provided. See Figure A. STEP 3. Attach fan switch to fan switch bracket using two #8x1/2” plated, Phillip head screws provided. The 2” flange on the

bottom of bracket and terminals on the fan switch should be toward the back of the heater when properly installed. STEP 4. Locate the two engagement holes in base of heater. On a 35,000 Btu heater these holes are approximately 6-1/2” from the

back edge and right and left holes are 5-1/4” and 7-1/4” respectfully from the right side (as viewed from back of heater). On a 50,000 Btu heater the holes are approximately 10-3/4” from the back edge and right and left holes are 5-3/8” and 7-3/8” respectfully from the right side. Attach fan switch bracket to base using two #8x1/2” hex head screws provided. This will require a ¼” socket and ratchet. See Figure A.

STEP 5. Locate the blower opening and mounting tab on the base of the heater. Insert the front flange of the blower housing under the mounting tab, lower the back of the blower down onto the base aligning the clearance holes in the blower base with the engagement holes in the heater base. Secure the blower to the base with two #8 screws provided. See figure A.

STEP 6. Connect black wire from junction box to right fan switch terminal. See Figure B. STEP 7. Connect white wire from junction box to white fan motor wire. See Figure B. STEP 8. Connect black wire from fan motor to left fan switch terminal. See Figure B.

STEP 9. Turn variable speed control switch clockwise “If any part of the original wire as suppied (as viewed from front of unit) to “OFF”. STEP 10. Plug power cord into 115 V. grounded receptacle.

STEP 11. Turn variable speed control switch counterclockwise with the appliance must be replaced, it (as viewed from front of unit) from “OFF” to “HIGH”. Blower will now cycle on automatically when the switch temperature is met after the main burner comes on. The blower will continue to run for a short period after the main burner goes off. Blower speed can be adjusted by setting the variable speed control switch between high and low.

WARNING: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Heat Shield

 

 

 

Junction

 

 

BLACK

Box

 

 

WHITE

 

 

Control

 

 

Speed

 

 

FAN

 

 

 

 

 

MOTOR

SWITCH

Power

 

 

WHITE

Cord

 

 

GREEN

 

 

BLACK

 

 

 

Fan Switch

 

 

MOTOR SPEED

Bracket

 

 

 

 

CONTROL

 

 

 

Blower

 

 

“If any part of the original wire as suppied

Housing

 

 

 

 

 

with the appliance must be replaced, it

 

 

 

must be replaced with a wire of at least

 

 

 

a 105 degree C temperature rating.”

Mounting Tab

 

 

 

 

 

 

FIGURE B

FIGURE A

 

 

 

 

Page 13

Page 13
Image 13
Louisville Tin and Stove VC501A CHB-3BLOWER INSTALLATION, “If any part of the original wire as suppied, Figure B, Figure A