3.3.1 Electrical Characteristics
Table 3.3 lists the maximum power requirements for standard Ultra320 SCSI to
Table 3.3 Maximum Power Requirements
Host | PCI PRSNT1#/ | Over the | ||
Adapter | +5.0 V | +3.3 V | PRSNT2# Power | Operating Range |
|
|
|
|
|
LSI20320 | 1.5 A | 2.0 A | 15 W | 0 ˚C to 55 ˚C |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
|
|
LSI21320 | 1.5 A | 2.5 A | 15 W | 0 ˚C to 55 ˚C |
|
|
|
| |
|
|
|
|
|
LSI22320 | 5 A | 0.0 A | 25 W | 0 ˚C to 55 ˚C |
|
|
|
| |
|
|
|
|
|
3.3.2 Thermal and Atmospheric Characteristics
The thermal and atmospheric characteristics for all Ultra320 SCSI Host Adapter boards are:
• Temperature range: 0 ° C to 55 ° C (dry bulb)
•Relative humidity range: 5% to 90% noncondensing
•Maximum dew point temperature: 32 ° C
•Airflow must be sufficient to keep the LSI53C1020 and LSI53C1030 heat sink temperature below 80 ° C
The following parameters define the storage and transit environment for the Ultra320 SCSI Host Adapter boards:
• Temperature range: 40 ° C to 105 ° C (dry bulb)
•Relative humidity range: 5% to 90% noncondensing
Technical Specifications |
Rev. 2.0 | Copyright © 2002 by LSI Logic Corporation. All rights reserved. |