Environmental Requirements

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Requirements

Environmental Requirements

Table 8 Drive Module and E2400 Command Module Environmental Requirements

Element

Unit of Measure

E3300 and FC-1 10x

FC-1 14x and E2400 14x

Requirement

Requirement

 

 

 

 

 

 

 

Optimum

22º C (72º F)

22º C (72º F)

 

Operating Range

10º C to 40º C (50º F to 104º F)

10º C to 40º C (50º F to 104º F)

Temperature

Storage Range

-10ºC to 50º C (14º F to 120º F)

-10ºC to 50º C (14º F to 120º F)

 

Transit Range

-40ºC to 60º

-40ºC to 60º C

 

(-40ºF to 140º F)

(-40ºF to 140º F)

 

 

Temperature

Operating Range

10º C (18º F) per hour

10º C (18º F) per hour

 

15º C (27º F) per hour

15º C (27º F) per hour

Change

Storage Range

(Max. Allowed)

 

 

 

Transit Range

20º C (36º F) per hour

20º C (36º F) per hour

 

 

Operating Range

20% to 80%

20% to 80%

 

 

 

 

 

Storage Range

10% to 90%

10% to 90%

Relative Humidity

 

 

 

Transit Range

5% to 95%

5% to 95%

(No Condensation)

 

 

 

 

Max. Dew Point

26º C (79º F)

26º C (79º F)

 

Max. Gradient

10% per hour

10% per hour

 

 

 

 

Sound

Sound Power

6.0 bels

6.0 bels

 

 

 

Sound Pressure

60 dBA

60 dBA

 

 

 

 

 

 

Operating Range

30.5 m (100 ft.) below sea level

 

3000 m (9840 ft.) above sea level

 

 

 

 

 

Altitude1

Storage Range

30.5 m (100 ft.) below sea level

3000 m (9840 ft.) above sea level

 

 

 

 

 

 

Transit Range

30.5 m (100 ft.) below sea level

 

12,000 m (40,000 ft.) above sea level

 

 

 

 

 

 

1If you plan to operate the drive module or E2400 command module at altitudes between 1000 m (3280 ft.) and 3000 m (9850 ft.), lower the environmental temperature 1.7º C (3.3º F) for every 1000 m (3280 ft.) above sea level.