. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drive Module Power Requirements

FC-1 10x Drive Module and E2400 10x Command Module

The AC power source must provide the correct voltage, current, and frequency specified on the manufacturer’s nameplate. Internal AC power units for rackmount cabinets must be able to handle the power requirements for these units (Table 12).

Table 12 FC-1 10x and E2400 10x Power Requirements

Item

Unit of Measure

 

Requirement

 

 

 

Circuit Breaker

3.0 A (slow-blow fuse per power supply)

 

 

 

 

 

 

USA

International

 

 

 

 

 

Nominal Voltage

90 to 136 VAC

198 to 264 VAC

 

 

 

 

Drive Module and

Frequency

50/60 Hz

50/60 Hz

 

 

 

Command Module

 

 

 

Idle Current

3.39 A

1.45 A

AC Power

 

 

 

 

Maximum Operating Current

3.53 A

1.50 A

 

 

 

 

 

Maximum Surge Current (10-

5.19 A

2.10 A

 

drive spin up)

 

 

 

 

 

 

 