LEAK TEST

Do not use an open flame to check for leaks.

Do not remove valve orifices.

Do not smoke during testing.

Do not test indoors. Always test outdoors in a well-ventilated area.

Test for leaks each time the propane canister is replaced.

Use a solution of mild soap (liquid dish soap works well) and water for testing

TEST PROCEDURE

1.Visually inspect all hoses before each use. If there is excessive abrasion, wear, or cutting, replace the hoses before further use. Replace defective hoses only with those specified

by the manufacturer.

2. Be sure that the valve

 

Burner

is in the off position.

 

 

 

3. Be sure that the natural

 

 

gas delivery hose is correctly

 

 

and securely connected.

 

 

Venturi Tube

4. Using a small paint brush, spread

 

 

 

a thin coating of the soap/water

 

 

solution onto the following

 

Inspection Panel

connections:

 

 

Oriface

 

 

 

 

 

Residential Gas Supply

 

 

Gas Delivery Hose

Natural Gas Supply Hose

 

 

 

 

 

 

 

 

 

Valve

Gas Supply Hose - Valve Inlet

 

 

 

Valve Outlet - Gas Delivery Hose

 

 

5.If the soap/water solution bubbles

there is a leak. Immediately

 

Gas Supply Hose

 

disconnect the gas supply and check

 

 

connections. Reconnect the gas

 

 

Natural Gas Inlet

 

 

supply and repeat the test.

 

 

 

6.If the soap/water solution continues to bubble, remove the gas supply

hose and replace the defective parts

Access Panel

before using grill.

Natural Gas

Supply Hose

9

Page 9
Image 9
Magma DM10-016NG owner manual Leak Test, Residential Gas Supply, Natural Gas Supply Hose