INSPECTION FOR SPIDERS

Spiders, Earwigs, and other insects find the venturi tube and burner of barbeques to be ideal nest building areas. Webs, or the insects themselves, can block the flow of gas, which may cause flashback (a fire in the venturi tube). Always inspect these areas prior to operation of the grill.

Inspection Procedure:

Igniter Electrode

1.

Be sure that the

4. Remove the grill

5. Remove the

6. Remove the burner by

2.

grill is cold.

grate by depressing

Radiant Plate

unscrewing it counter-

Be sure that

the grate at the

and Dome.

clockwise. Take care not

3.

gas is off.

tabs and turning

 

to damage the igniter

Open the lid.

the grate clockwise

 

electrode. Inspect the

 

 

until it is free of

 

burner at this time and

 

 

the holding clips.

 

clean as required.

7. Open the

8. Depress the thumb

9. Visually inspect

10. Clean the tube

Inspection Panel

clip holding the gas

the venturi tube

by running a

on the rear of

delivery hose to the

for obstructions.

small brush or

the column.

venturi tube and

 

similar cleaning

 

pull the hose free.

 

item through the

 

 

 

venturi tube

11. When the blockage has been

removed, replace the gas delivery hose into the venturi tube by depressing the thumb clip and inserting the hose until the thumb clip snaps into place.

Igniter Electrode and electrode protection cap

12. Replace the burner by screwing it clockwise

until snug on

to its threaded tube, Once again being careful not to damage the igniter electrode. Insure that one of the two electrode protection caps is directly above the electrode.

13.Replace the radiant plate and dome and the grill grate.

8

Page 8
Image 8
Magma DM10-016NG owner manual Inspection for Spiders, Inspection Procedure