4.Attach the fan assembly to the fan bracket provided in the log box. Use #10 sheet metal screws provided with fan kit. Do not remove finger guard screws.(Fig. 10)

Snapstat

Wire

Rheostat

Wire

Fan

Bracket

Finger Guard

ST669

Fig. 10 Attach the fan assembly to the fan bracket.

5.Connect snapstat leads. Disconnect the snapstat module from the leads inside the snapstat bracket. (Fig. 11) Bend open the snapstat bracket. Use needlenose pliers to remove the black plastic grommet from the bracket. Discard the bracket. Insert the grommet and wires into the large hole at the bottom right corner of the inner shroud. Feed the snapstat wire leads through the grommet into the stove interior. Connect the two wires to the two snapstat extension leads attached to the inner shroud.

Snapstat Bracket

Snapstat Module

Pinch

Grommet to

Remove

ST670

Fig. 11 Remove the snapstat and grommet from the bracket and insert the grommet into the inner shroud.

6.Position the fan assembly so the ducts slide be- tween the inner and outer shroud. The inner shroud should engage with the two slots in the ends of the bracket so that bracket and shroud are interlocked.

(Fig. 12) Secure the bracket with the four sheet metal screws provided in the finish bag.

7.Route the rheostat wire assembly to the right between the inner and outer shroud. Run the wire through the slots at the bottom right corner of the inner shroud.

8.Refasten the outer shroud to the inner duct assem- bly.

Outer

Slot

Shroud

 

 

{Inner Shroud}

 

Slot

 

ST194

Fig. 12 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws.

9.Install the snapstat by loosening the front screw on the inner side of the duct (Fig. 13) slide the snapstat under the head of the screw and tighten. Connect the leads to the snapstat. Make sure the snapstat assembly is mounted straight front to back.

Left Air Duct

Snapstat

 

ST671

Fig. 13 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan before gas line connection.

10.Slide shroud assembly over the sides and fasten the four screws loosened earlier.

11.Plug the power cord into a standard grounded 110 volt household outlet. If the fan control knob is not turned to the OFF position, the fan will turn on when the temperature at the snapstat reaches approximately 109°F.