Image 18
Troubleshooting

Vermont Castings Radiance Vent-Free Gas Heater

Troubleshooting

Follow these procedures in the order presented.

W A R N I N G

TURN OFF HEATER AND ALLOW TO COOL

COMPLETELY BEFORE SERVICING.

CONDITION

POSSIBLE CAUSE

SOLUTION

No spark at pilot when Ignitor is operated.

1.Ignition Electrode is disconnected from ignition wire, broken or incorrectly positioned.

2.Ignitor wire is broken.

3.Bad Piezo Ignitor.

1.Inspect and re-connect, replace or repair as necessary.

2.Replace wire.

3.Replace Piezo Ignitor.

The Ignitor Electrode sparks, but Pilot does not light.

1.Gas supply is turned off or supply line shut-off valve is closed.

2.Control Knob is not in PILOT position.

3.Control Knob not pressed in while in PILOT position.

4.Air present in gas lines.

5.Inlet supply pressure is not within correct settings.

1.

Turn on gas supply or open

 

supply line shut-off valve.

2.

Turn Control Knob to PILOT.

3.

Press Control Knob in while in

 

the PILOT position.

4.

Continue holding in Control Knob

 

and repeat ignition procedure

 

until air is bled from the lines.

5.

Call local gas supplier. Adjust

 

inlet supply pressure to specifica-

 

tion: NG; 5.5Ó w.c.-14.0Ów.c. LP;

 

11.0Ó w.c.-14.0Ów.c.

6. Other conditions that should be identified only by a qualified gas technician.

 

 

 

Piezo Ignitor

 

 

 

 

 

 

 

TH

 

 

 

 

PILOT

OFF

 

 

 

 

TP

 

I

L

 

 

 

 

 

 

 

H

ON

 

 

 

O

 

TPTH

 

 

 

 

 

 

 

 

 

PILOT ADJ

 

 

Regulator

 

 

 

HV104

 

 

 

 

Pilot / Main Control

Fig. 34

Honeywell valve assembly.

 

 

18

 

 

 

 

 

6. Call qualified gas technician.