Vermont Castings Radiance |
| ||
|
| Install ON/OFF Switch | |
|
| The switch assembly parts are found in the parts bag. | |
|
| 1. Attach switch assembly to left rear side of stove | |
|
| shroud using two screws and existing holes in | |
|
| shroud. (Fig. 16) |
|
| Rheostat | 2. Run wires down back of stove, under bottom of rear | |
|
| shroud to valve. |
|
|
| 3. Attach wires to valve terminals. (Fig. 17) | |
Retaining Nut |
|
|
|
Control Knob | ST347a | Switch | Existing |
|
| Assembly | |
|
| Holes | |
Fig. 14 Attach rheostat to control panel. Valve may look |
| ||
|
| ||
different. |
|
|
|
MOTORDisconnect power before servicing.
BLK | BLK | BLK | SNAPSTAT |
|
|
|
| Screws | ST315 | |
|
|
| ||
BLK | WHT | Fig. 16 Attach switch assembly to rear shroud. | ||
|
| |||
WHT GRN | RHEOSTAT |
|
| |
| ON/OFF |
|
| |
POWER |
|
|
| |
| ST196 | TH |
| |
|
|
| ||
Fig. 15 #2767 / FK26 Fan Wiring Diagram | TP |
| ||
|
|
| ||
| WARNING | TPTH |
| |
The optional fan kit is equipped with a three- |
| |||
|
| |||
prong (grounding) plug for your protection against |
|
| ||
shock hazard and should be plugged directly into |
|
| ||
a properly grounded |
| ST228 | ||
cut or remove the grounding prong from this | Fig. 17 Attach switch wires to valve. | |||
plug. |
|
|
| |
NOTE: If you are installing the fan kit after the stove is | Thermostat Connection (Optional) | |||
Use only a thermostat rated for 500 - 750 millivolts. | ||||
in its final location, follow same steps mentioned | ||||
Do not use low voltage (24V) thermostats. | ||||
previously with the exception of disengaging only the | ||||
|
| |||
right side of the outer shroud. | Check the table below for the appropriate gauge | |||
|
| thermostat wire to use for the length of lead required in | ||
|
| your installation. |
| |
|
| Thermostat Wire / Gauge | Maximum Run | |
|
| 18 | 40 feet | |
|
| 20 | 25 feet | |
|
| 22 | 16 feet | |
|
| 1. Install the wall thermostat in the desired location and | ||
|
| run the wires to the stove location. Terminate these | ||
|
| leads with 1/4Ó female connectors. | ||
|
| 2. Connect the thermostat wires to the valve. (Fig. 17) |
12 | 20004555 |