Majestic Appliances 3379 Install ON/OFF Switch, Thermostat Connection Optional, plug, 20004555

Models: 3377 3378 3371 3376 3372 3370 3373 3374 3379 3375

1 26
Download 26 pages 25.32 Kb
Page 12
Image 12
Install ON/OFF Switch

Vermont Castings Radiance Vent-Free Gas Heater

 

 

 

Install ON/OFF Switch

 

 

The switch assembly parts are found in the parts bag.

 

 

1. Attach switch assembly to left rear side of stove

 

 

shroud using two screws and existing holes in

 

 

shroud. (Fig. 16)

 

 

Rheostat

2. Run wires down back of stove, under bottom of rear

 

 

shroud to valve.

 

 

 

3. Attach wires to valve terminals. (Fig. 17)

Retaining Nut

 

 

 

Control Knob

ST347a

Switch

Existing

 

 

Assembly

 

 

Holes

Fig. 14 Attach rheostat to control panel. Valve may look

 

 

 

different.

 

 

 

MOTORDisconnect power before servicing.

BLK

BLK

BLK

SNAPSTAT

 

 

 

 

Screws

ST315

 

 

 

BLK

WHT

Fig. 16 Attach switch assembly to rear shroud.

 

 

WHT GRN

RHEOSTAT

 

 

 

ON/OFF

 

 

POWER

 

 

 

 

ST196

TH

 

 

 

 

Fig. 15 #2767 / FK26 Fan Wiring Diagram

TP

 

 

 

 

 

WARNING

TPTH

 

The optional fan kit is equipped with a three-

 

 

 

prong (grounding) plug for your protection against

 

 

shock hazard and should be plugged directly into

 

 

a properly grounded three-prong outlet. Do not

 

ST228

cut or remove the grounding prong from this

Fig. 17 Attach switch wires to valve.

plug.

 

 

 

NOTE: If you are installing the fan kit after the stove is

Thermostat Connection (Optional)

Use only a thermostat rated for 500 - 750 millivolts.

in its final location, follow same steps mentioned

Do not use low voltage (24V) thermostats.

previously with the exception of disengaging only the

 

 

right side of the outer shroud.

Check the table below for the appropriate gauge

 

 

thermostat wire to use for the length of lead required in

 

 

your installation.

 

 

 

Thermostat Wire / Gauge

Maximum Run

 

 

18

40 feet

 

 

20

25 feet

 

 

22

16 feet

 

 

1. Install the wall thermostat in the desired location and

 

 

run the wires to the stove location. Terminate these

 

 

leads with 1/4Ó female connectors.

 

 

2. Connect the thermostat wires to the valve. (Fig. 17)

12