ELECTRICAL CONNECTION

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation. The unit comes standard with a 6 ft. (1828mm) long three wire cord, exiting the right side of the fireplace. Plan the installation to avoid the use of an extension cord. If an extension cord must be used, it must be a minimum 16AWG, three wire with grounding type plug and connector and rated not less than 2025 Watts.

A new electrical outlet can be installed inside the frame construciton, if permitted by local codes.

Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock and injury to persons.

Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the electrical system which has been under water.

Hard (Direct) Wire Connection

If desired, a qualified electrician may remove the cord conection and wire this unit directly to the household wiring.

Any electrical re-wiring of this appliance must be done by a qualified electrician.

WARNING: This fireplace comes with an optional manual circuit breaker reset beside the On/Off switch. In case the fireplace is not operating check the circuit breaker and reset the button at the breaker. If the fireplace is still not operating immediately call a qualified service technician to inspect the fireplace.

INSTALLATION OF LOGS

1.Turn off power to the unit.

2.Remove front glass (See "Glass Removal" section).

3.The log bottom is shipped in place. No adjustment is necessary.

HE32EF / DEF33 *

Fig. 4

 

 

* HE32EF / DEF33 is a unitized log set.

CERAMIC REFRACTORY INSTALLATION

1.Remove the glass assembly.

2.Slide refractory panels on either side of the firebox between firebox side and the upper lintel baffle.

3.Push panels against firebox side. If desired, secure the panels to the sides of the firebox with some adhesive, such as silicone.

4.Replace glass frame and upper louvre panel.