P 10/ 12

Wiring diagram

Fig. D-4

Wiring to Switch

Fix the FET Lead wires as follows:

yellow with Lead wire holder nearest to Switch trigger blue with the center Lead wire holder

black with Lead wire holder farthest from Switch trigger

FET

black blue yellow

Lead wire

holder FET

Switch trigger

Connect the Lead wires to Switch, tilting their Connectors to 45 degrees as drawn below.

45 degrees

Fig. D-5

with Battery fuel gauge available for the countries

other than North American countries

Brush holder complete

Put Pigtail of Carbon brush in the area marked with gray color to avoid pinching with Rear cover.

Wiring in Housing L

9 mm

9 mm

Put Line filter in

 

 

 

 

 

 

this place.

Line filter

Pig tail of Carbon brush

Put the bundled Lead wires into the groove of Sponge.

Seal

Pay attention, not to put

Lead wires on the Seal.

Lead wires connected to Connector have to be fixed with Lead wire holders.

Sponge

Connector

Light circuit

Page 10
Image 10
Makita BDF448 dimensions Fig. D-4