8.PREPARATION FOR STORAGE

-Remove fuel strainer cup, open fuel cock and completely drain fuel from tank. -After draining fuel, reinstall strainer cup and close the fuel cock.

-Start and run the generator without an appliance connected until the carburetor is completely empty of fuel.

-Change old lubricating oil with fresh oil.

-Clean air cleaner element.

-Remove spark plug and pour 5-10 cc (1 fl.oz.) of lubricating oil through the plug hole. Then pull starter handle several times and reinstall the spark plug.

-Check for loose bolts and nuts. Retighten if necessary.

-Clean generator throughly and spray completely with a preservative spray if available.

-Be sure to place engine switch at the "STOP" position.

-Pull starter handle until resistance is felt and leave it in that position.

-Storage indoors in a well-ventilated, low humidity area is recommended.

CAUTION]

Extreme care must be taken when draining fuel tank. Never use water to clean the generator.

- 17 -

Page 20
Image 20
Makita G1200R instruction manual Preparation for Storage