ENGLISH
SETUP
PLC SETTING
RECALIBRATION
If audio is lost when the ZC4001 and ZR6001 are connected over a PLC connection, recalibrate the signal to the best carrier frequency.
The ZR6001 is set first.
<ZR6001>
Using the OSD menu system, set “MULTI PLC SERVER” to “ON”.
ZR6001 ON SCREEN DISPLAY MENU SYSTEM9 MU L T I P L C
MU L T I P L C S E R V E R : ON
CONN E C T I ON MOD E :
AU T O |
| ||
H I GH | AUD I O QUA L I T Y | ||
H I GH | R E L I AB I L I T Y | ||
GP |
| I D S E T T I NG : S T AR T | |
| |||
MA I N | E X I T |
1. Select “9. MULTI PLC” in the SETUP MAIN MENU with the or cursor buttons, and
<ZC4001>
1. 2.
1 .
1. Press and hold the ENTER button for 5 sec. or more.
2. Press the ENTER button.
SET GROUP ID
To set a Group ID, connect the AC power cables of the ZC4001 and ZR6001 to wall power outlets as close to each other as possible.
Set the Group ID simultaneously for the ZC4001 and ZR6001.
<ZR6001>
Using the OSD menu system, set “GP - ID SETTING” to “START”.
ZR6001 ON SCREEN DISPLAY MENU SYSTEM9 MU L T I P L C
MU L T I P L C S E R V E R : ON
CONN E C T I ON MOD E :
AU T O |
| ||
H I GH | AUD I O QUA L I T Y | ||
H I GH | R E L I AB I L I T Y | ||
GP |
| I D S E T T I NG : S T AR T | |
| |||
MA I N | E X I T |
1. Select “9. MULTI PLC” in the SETUP MAIN MENU with the or cursor buttons, and press the ENTER button.
2. Select
3. Simultaneously press the ENTER buttons of the ZR6001 and ZC4001.
<ZR6001>
<ZC4001>
The below message appears when the Group ID has been successfully set.
<ZC4001>
<ZR6001>
The below message appears if the units fail to set the Group ID.
<ZC4001>
press the ENTER button.
2. Select “MULTI PLC SERVER” with theor cursor buttons. And select “ON” with theor cursor buttons.
For details, see page 24 in the ZR6001 User’s Guide.
3. T h e b e l o w m e s s a g e a p p e a r s w h e n | <ZC4001> |
recalibration is complete. | 1. 3. 2. |
1 .
1. Press and hold the ENTER button for 5 sec. or more.
2. Press the button once.
<ZR6001>
Notes:
One possible reason the Group ID cannot be set is power line noise. In that case, unplug the power cable of the device that is generating noise, then plug it back in and try setting the Group ID again.