Environmental

Parameter

IEC 60954 Classification

Degree of Protection

Operating Temperature

Storage Temperature

Relative Humidity

Vibration

Rain and Spray

Solar Radiation

Corrosion (Salt Mist)

Electromagnet Emission

Electromagnetic Immunity

Safety Precautions

Value

Exposed

IP67

-25°C to 55°C -40°C to 70°C

93%RH @40° per IEC60945-8.2

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7

12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8

Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12

Conducted and Radiated Emission per IEC 60945-9

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12