Maretron M001101 user manual Technical Support, Environmental

Models: M001101

1 17
Download 17 pages 42.71 Kb
Page 15
Image 15

®

Environmental

Parameter

IEC 60954 Classification

Degree of Protection

Operating Temperature

Storage Temperature

Relative Humidity

Vibration

Rain and Spray

Solar Radiation

Corrosion (Salt Mist)

Electromagnet Emission

Electromagnetic Immunity

Safety Precautions

Value

Exposed

IP67

-25°C to 55°C -40°C to 70°C

93%RH @40° per IEC60945-8.2

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7

12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8

Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12

Conducted and Radiated Emission per IEC 60945-9

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12

7 Technical Support

If you require technical support for Maretron products, you can reach us in one of the following ways:

Telephone:

1-866-550-9100

Fax:

1-602-861-1777

E-mail:

support@maretron.com

World Wide Web:

http://www.maretron.com

Mail:

Maretron, LLC

 

Attn: Technical Support

 

9034 N. 23rd Ave Suite 13

 

Phoenix, AZ 85021 USA

Revision 1.0

Page 11

Page 15
Image 15
Maretron M001101 user manual Technical Support, Environmental