APPLICATION INSTRUCTIONS
APPLICATION INSTRUCTIONS FOR TOTAL CONCEPT CLEANING OF BOILER
SIZE: 1 Gallon PART NUMBER: 20 - 0307
GENERAL NOTES:
Market Forge R has two basic types of boilers; one has an automatic drain valve, the other has a manual drain valve. To determine which type you have, open cabinet doors and you will see a control box with two switches and an indicator light. The instruction label on the control box will identify the boiler as being either automatic or manual. Those boilers designated as being automatic must be energized in order to close the drain valve.
Total Concept is designed to be used with water between 160°F to 200°F.
Preheating is required on both automatic and manual boilers to raise the water temperature to the acceptable range. (160°F to 200°F).
For manual boilers, make certain drain valve is tightly closed.
On Market Forged boilers manufactured after 8/84; your unit is equipped with an access plug in the steam header line. This location should be used to add cleaner/des- caler to boiler chamber during maintenance.
On Market Forged boilers manufactured before 8/84; ac- cess to boiler chamber should be gained through either the
Total Concept is a NSF listed nonfood product. This is a liquid acid (nonmuriatic) product that works without fumes, odors, and hazards associated with other harsh chemicals.
BOILER TREATMENT CLEANING INSTRUCTIONS: After determining proper location for cleaner/descaler to be added: Read complete instructions thoroughly; in- cluding all warning and cautionary statements.
Fig. 1
1. Energize boiler and fill to operating level.
Fig. 2
2. Energize heating circuit to
Fig. 3
Fig. 4
3.AUTOMATIC - After unit is