Marley Engineered Products 994 manual Assemble Switch Cup To Fan

Models: 994

1 8
Download 8 pages 48 b
Page 4
Image 4
ASSEMBLE SWITCH CUP TO FAN

HANGING FAN MOTOR AND MAKING ELECTRICAL CONNECTIONS

Lift motor with ball hanger assembly attached and position into ball hanger bracket, making sure slot in ball hanger locks onto ball hanger bracket’s ball locking stud. Connect motor leads to 120V, 60 cycle supply wiring in accordance with FIgures 5 and 13. Connect ground wire from supply to green ground wire on top of ball hanger. The white lead from the motor is connected to the white supply wire. The black lead from the motor is connected to the black supply wire to permit fan operation. Both the black and blue fan motor leads are connected to the black supply wire when a light kit is to be installed, permitting both fan and light operation. (See Figure 5.) Note that connections should be made outside the canopy. In some cases, it may be necessary to splice additional wire to existing wiring in order to make connections.

a

CAUTION !

1.Electrical connections should be in accordance with the National Electrical Code and/or all local codes that may apply.

2.To avoid possibility of serious injury or electrical shock, the installer must disconnect the electrical circuit supplying power to the fan outlet box prior to installing the ceiling fan.

3.Damp location ceiling fans must be installed in a GFCI protected circuit.

Once the electrical connections have been made, carefully position the leads with the connections pointed upwards inside the canopy or outlet box. Position the ground wire (green and bare connected wires) and the white connected wires on one side of the outlet box and/or canopy; the black connected wires on the opposite. Slide the canopy up to the ceiling making sure the canopy mounting screw heads pass through the key-way slots. Rotate the canopy towards the narrow end of the key-way and tighten the canopy mounting screws. See Fig. 5 & 6.

FIG. 5

WHITE CONNECTED WIRES

FIG. 6

120V. 60HZ. SUPPLY

OUTLET BOX APPROVED

 

 

FOR FAN SUPPORT

 

 

CEILING MATERIAL

CEILING

 

 

 

GREEN & BARE FIELD

 

BLUE

WIRE (GND.) CONNECTION

 

BLACK CONNECTED

BALL HANGER BRACKET

CHECK DOWNROD

 

WIRES

BALL HANGER SET

 

MOUNTING HUB SET

 

SCREW

CANOPY MOUNTING

 

SCREWS

SCREWS

BALL HANGER

 

 

CANOPY IN DOWN

 

BALL HANGER DOWNROD

POSITION

 

DOWNROD MOUNTING HUB

MOTOR HOUSING

 

SET SCREWS

 

 

TOP COVER

 

 

 

FIG. 7

FLUSH WITH

CEILING

CANOPY MOUNTING

SCREWS

ASSEMBLE SWITCH CUP TO FAN

1.Connect the switch cup plug to the fans connector plug, taking care to align the guides in each part. This ensures proper electrical circuit connection (matching lead colors).

2.Remove one screw from the switch cup mounting plate, and loosen the remaining two screws.

3.Position the switch cup onto fan’s remaining two switch cup mounting plate screws and twist to latch cup in place. With cup latched at extreme ends of latching cutouts, replace and secure the removed screw into the switch cup mounting plate through the cup’s screw hole. Tighten the other two screws loosened in Step 2.

4.Reconnect the supply power to the fan circuit. Make sure fan’s pull chain switch is in the off position (hub is not turning) following connection of the power and prior to performing the next steps.

SWITCH CUP

MOUNTING PLATE

SWITCH CUP

SECURING SCREWS

FAN

SWITCH CUP

FAN PULL CHAIN

SWITCH

CONNECTOR

PLUGS

— 4 —

Page 4
Image 4
Marley Engineered Products 994 manual Assemble Switch Cup To Fan