!WARNING

DO NOT ATTEMPT

to assemble blades until you have read thoroughly and understand completely all instructions. To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

a

CAUTION !

ALTHOUGH THE BLADE ARMS ARE INSPECTED AT OUR FACTORY, CARE MUST BE TAKEN IN THE

ASSEMBLY OF THE BLADES SO AS NOT TO DEFORM OR ALTER THE BLADE ARM.

BE CAREFUL NOT TO SLIDE OR SCRAPE METALLIC PARTS ON BLADE’S SURFACE.

BLADE ASSEMBLY INSTRUCTIONS

1.Open the motor assembly carton and remove the blades carefully, being sure not to scratch the factory finish. If the blades are preassembled, proceed to the next section; if not, proceed as follows:

2.In the carton, locate the hardware bag and blade arms. (See Fig. 8)

3.Remove the truss-headed machine screws and washers from the hardware bag. Some assemblies may not require washers.

4.Insert screws (10-24 x 3/8”) through the washers, blade and into the threaded emboss on the blade arm. Assemble, but do not tighten.

5.After all screws are in place in the blade assembly, alternately tighten each screw evenly until the assembly is secure.

6.Check assembled blade for looseness between the blade arm and blade. If present, continue tightening alternate screws until secure.

7.Repeat the above procedure for the remaining blades and hardware.

8.Once the blade assembly is complete, proceed with installation.

ATTACHING FAN BLADES TO MOTOR HUB (See Fig. 10)

This unit is designed with the capability of being a four or five bladed fan depending on the customer’s preference. Once the number of blades to be installed has been decided on, perform the following steps carefully to minimize fan wobble and insure proper fan balance.

1.Please find embossed onto the motor hub the numbers 4, 5 and their guide lines. The 4 and 5 represent the number of blades to be installed and the guide lines locate the specific screw holes to be used for that blade combination. On some models this may be in the form of square holes (used for four blade installations) and round holes (used for five blade installations). (See Fig. 9)

2.First remove and discard the transport bumpers and screws. Position the arm of the assembled blade on the bottom of the hub. Using the guide lines align the two tapped holes in the hub with the two holes in the blade arm. Insert the two 10-32 truss head screws into these holes. Tighten the screws down and then back them off slightly (Approx. 112 turns).

FIG. 10

FIG. 8

FAN BLADE

SCREWS

PETAL

MOTOR

HUB

WASHER

7 FT. MINIMUM HEIGHT FROM FLOOR LEVEL

“10-32 X 1/2”

LONG SCREWS

BLADE ARM

BENEATH

MOTOR HUB

BLADE ARM

MOUNTING

SCREW

GUIDE LINES

FLOOR LEVEL

BLADE

QUANTITY

FIG. 9

— 5 —

Page 5
Image 5
Marley Engineered Products 994 manual Blade Assembly Instructions, Do not Attempt

994 specifications

Marley Engineered Products 994 is an innovative solution in the market for heating, ventilation, and air conditioning (HVAC) systems. Designed with cutting-edge technology and efficiency in mind, the 994 model is particularly recognized for its ability to provide reliable and uniform temperature control in a variety of environments.

One of the standout features of the Marley 994 is its fan-assisted convective heating design, which allows for quick and effective heat distribution throughout a space. This model is equipped with a high-performance fan that operates quietly and efficiently, significantly improving comfort levels in both residential and commercial settings. The fan's adjustable speed settings enable users to optimize airflow according to specific heating needs, making it a versatile choice for various applications.

In terms of technology, the Marley 994 incorporates advanced controls that enhance usability and efficiency. Its digital thermostat offers precise temperature management, allowing users to set and maintain their desired comfort levels effortlessly. The programmable timer feature provides added convenience, enabling users to schedule heating operations around their routine, thus saving energy and reducing operational costs.

The construction quality of the Marley 994 is another characteristic that sets it apart. It's designed with rugged materials to ensure durability and long-lasting performance, even in demanding environments. The unit is also lightweight and compact, which simplifies installation and integration into existing HVAC systems.

Moreover, the Marley 994 is engineered with safety in mind. It includes a variety of safety features, such as overheating protection and automatic shut-off mechanisms, to prevent accidents and ensure reliability during operation. This commitment to safety enhances its appeal for both homeowners and commercial facility managers.

Energy efficiency is a hallmark of the Marley 994, as it conforms to the latest energy standards and regulations. This model provides significant energy savings, which not only benefits users financially but also supports sustainability efforts.

Overall, Marley Engineered Products 994 combines high-performance heating capabilities with advanced technology, durable construction, and safety features, making it an exceptional choice for those seeking effective HVAC solutions. Its versatility and efficiency make it suitable for a wide range of applications, ensuring reliable comfort no matter the setting. As the demand for efficient heating solutions continues to rise, the Marley 994 stands out as a leader in the industry.