GENERAL INSTALLATION (OPTIONS)
Various options for installing and operating these ceiling fans and accessories are available. Wiring diagrams are shown on the following pages. Refer to the instructions included with the light kit and/or speed control where applicable.
OPTION #1 (Fig. 11) Fan and light controlled at unit.
This installation is the simplest with all controls mounted on the fan as shipped. The light kit, if used, is controlled with the
OPTION #2 (Fig. 12) Fan controlled at unit. Light controlled at wall with switch or dimmer.
This option is the same as Option #1, except the light is controlled from an existing
FIG. 11
120 V. A.C. |
|
SUPPLY | CEILING BOX |
GROUND
BLACK
BLACK
WHITE WHITE
CEILING
BLUE
GREEN
BALL HANGER GROUND
WIRE SET SCREW
BALL HANGER
SET SCREW
BALL HANGER
CANOPY
MOTOR
SET SCREW
MOTOR
HOUSING
TOP
FIG. 12
120 V. A.C. | CEILING BOX |
|
|
|
|
|
|
| |
SUPPLY |
|
|
|
|
GROUND |
|
|
| |
BLACK | GND. |
|
|
|
WHITE |
|
|
| |
| BLUE |
| WALL CONTROL | |
WHITE | BLACK |
| CIRCUIT | |
WHITE |
| |||
|
|
| ||
| CEILING |
|
|
|
| BLACK |
|
|
|
| GREEN |
|
|
|
| BALL HANGER GROUND |
|
|
|
| WIRE SET SCREW |
|
|
|
BALL HANGER |
|
|
|
|
SET SCREW |
|
|
|
|
| BALL HANGER |
|
|
|
|
| GROUND | BLACK | WHITE |
| CANOPY |
|
|
|
| MOTOR | WALL MOUNTED |
|
|
MOTOR | HOUSING | LIGHT SWITCH |
|
|
SET SCREW | TOP | OR DIMMER |
|
|
|
| (USE ONLY LISTED |
| |
|
| GENERAL USE |
|
|
|
| SWITCHES) |
|
|
OPTION #3 (Fig. 13) Light controlled at unit. Fan controlled at wall by a Speed Control.
This option utilizes a speed control (See Chart 1) to operate the fan from a remote wall location. The light is controlled at the fan. The wall control replaces the existing wall switch. No additional wiring is necessary for this installation. The Fan switch on the unit must be left in the high speed position for the control to function properly. We suggest you cut off the chain of the
WARNING !
RISK OF FIRE - Fan speed switch must be set to high when wall speed control is used.
OPTION #4 (Fig. 14) Light controlled at wall. Fan controlled at wall by a Speed Control.
This option can be used when the fan is installed in place of an existing ceiling light kit. A speed control (See Chart 1) will replace the light switch (or dimmer) in the wall that controlled the ceiling light. An additional box and switch must be installed for this option. Follow all state and/or local building and electrical codes for this installation.
FIG. 13 |
|
|
|
| FIG. 14 |
120 V. A.C. | CEILING BOX |
|
|
| |
|
|
|
|
| |
SUPPLY |
|
|
|
|
|
GROUND | WHITE | GND. |
|
|
|
BLACK |
|
|
| ||
|
|
|
|
| |
WHITE WHITE | BLACK | BLACK |
| WALL CONTROL | |
|
|
| |||
|
|
|
|
| CIRCUIT |
| BLUE | CEILING |
|
| |
|
|
|
| ||
|
| GREEN |
|
|
|
|
| BALL HANGER GROUND |
|
| |
|
| WIRE SET SCREW | BLACK | WHITE | |
SET SCREW |
|
|
| ||
BALL HANGER |
|
|
|
|
|
|
| BALL HANGER |
|
| |
|
|
| GROUND | WHITE | BLACK |
|
|
| CANOPY |
|
|
MOTOR |
|
| MOTOR |
|
|
|
| HOUSING |
|
| |
SET SCREW |
|
| TOP |
|
|
SPEED CONTROL (USE ONLY LISTED CONTROLS)
120 V. A.C. | CEILING BOX |
|
|
|
| |
|
|
|
|
|
| |
SUPPLY |
|
|
|
|
|
|
GROUND |
| GND. |
|
|
|
|
BLACK | WHITE |
|
|
|
| |
|
|
|
|
| ||
WHITE WHITE | BLACK | BLACK |
|
|
|
|
|
|
|
|
|
| |
|
| RED | CEILING |
|
| |
|
|
|
|
|
| |
| BLUE | GREEN |
|
|
|
|
| BALL HANGER GROUND |
| GROUND | BLACKWHITE | ||
| WIRE SET SCREW |
| ||||
BALL HANGER |
|
|
|
|
|
|
SET SCREW |
| BALL HANGER |
|
|
| |
|
|
|
|
| ||
|
|
| CANOPY |
|
| |
MOTOR |
|
| MOTOR |
|
|
|
|
| HOUSING |
|
|
| |
SET SCREW |
|
| TOP | SPEED CONTROL |
| |
|
|
|
|
|
(USE ONLY LISTED CONTROLS)
WALL CONTROL
CIRCUIT
BLACK WHITE | BLACK | RED |
WALL MOUNTED
LIGHT SWITCH
OR DIMMER
(USE ONLY LISTED GENERAL USE SWITCHES)