Marley Engineered Products 994 manual Fan Operation, Reversible Operation, Lubrication, Light Kits

Models: 994

1 8
Download 8 pages 48 b
Page 6
Image 6
FAN OPERATION

3.Repeat the above procedure for the remaining blades.

4.Without delay, turn the fan on high speed for approximately one (1) minute.

5.Turn the fan off and let it stop by itself. DO NOT TOUCH BLADES OR HUB until the fan has stopped completely.

6.Being careful not to disturb the blade arm location on the motor hub, tighten all screws on the hub. This procedure allows final positioning of the blades to eliminate fan wobble. If wobble persists, loosen blades and repeat Steps 4 through 6.

NOTE: IF AFTER PERFORMING THE ABOVE PROCEDURE A WOBBLE IS STILL APPARENT, SWITCH ONE PAIR OF ADJACENT BLADES WITHOUT COMPLETELY TIGHTENING THE SCREWS. REPEAT STEPS 4 THRU 6.

FAN OPERATION

This ceiling fan has 3-speeds that are controlled by a pull-chain switch. Switch operation is OFF - HI - MED - LOW. The speed is easily changed by pulling the chain to select desired speed.

REVERSIBLE OPERATION

This ceiling fan is reversible. A slide switch installed either on the bottom of the motor assembly or on the side of the switch cap will reverse the direction of rotation. This will allow downward movement of air under the fan for summertime operation, or by reversing the direction of rotation, upward movement of air in the winter to recirculate hot air trapped at ceiling level. DAMP LOCATION FANS MAY NOT BE REVERSIBLE.

a

CAUTION !

DO NOT ATTEMPT TO CHANGE FAN DIRECTION WHILE UNIT IS OPERATING!

BEFORE ATTEMPTING TO CLEAN OR SERVICE YOUR CEILING FAN, DISCONNECT ELECTRIC POWER SUPPLYING THE FAN OUTLET BOX TO AVOID ELECTRICAL SHOCK OR PERSONAL INJURY.

LUBRICATION

The fan motor is constructed with sealed ball bearings which do not require lubrication during the life of the motor.

LIGHT KITS

Accessory light kits are available from your Marley Engineered Products Fan distributor. The wiring instructions for these kits are packed in the light kit carton.

WARNING !

Use only Light Kits marked “Suitable for use in Damp locations” with Damp location fans.

— 6 —