Marley Engineered Products A24DD manual Shutter Installation, WALL INSTALLATION MODEL 3130 SHUTTER

Models: A24DD

1 8
Download 8 pages 59.96 Kb
Page 5
Image 5
SHUTTER INSTALLATION

SHUTTER INSTALLATION

STEP 10 — Unpack Model A3024 shutter and read instruc- tions included. Note that the first part of the shutter instruc- tions refer to cutting the shutter hole, which you have already done, and so they may be disregarded. Follow the remaining instructions to adjust springs so that shutters open and close freely. (See Fig. 8.)

STEP 11 — Mount shutter to joists directly below fan opening with wood screws provided. Note sheet rock must be cover- ing center joist before shutter is installed. Again, make sure both sides of shutter open and close freely. (See Fig. 9.)

STEP 12 — Return to attic and attach side panels to fan as shown using remaining short screws and washers. (See Fig. 10.) Bottom of panels should rest upon ceiling. Bend flaps on ends of panels back when inserting panels between joists. These flaps will then spring back to seal off any space between panel and joist.

STEP 13 — Fan installation is now complete. With control in “OFF” position turn on 120V power supply to fan. Test run fan through all speeds.

WALL INSTALLATION MODEL 3130 SHUTTER

THIS INSTALLATION IS TO BE USED ONLY IN AN ATTIC GABLE OR WALL WHICH FACES AN UNOCCUPIED AREA, AN AREA NOT READILY ACCESSIBLE TO PEO- PLE OR ANIMALS! DO NOT USE THIS INSTALLATION IN AN ATTIC WITH ANY TYPE OF LOOSE INSULATION.

STEP 1 — Construct wood frame as shown in Figs. 11 & 12. Use 2 x 8 framing lumber and 2 x 2 furring strips.

STEP 2 — Drill (4) holes 14” in diameter in fan housing as shown in Fig. 13.

STEP 3 — Position fan in frame and secure with (4) wood or lag screws (#12 x 112” preferred) through holes drilled in Step 2. Note 334” dimension from edge of frame. (Fig. 14)

STEP 4 — Secure Model 3130 shutter with (8) wood or lag screws (#12 x 1” preferred) through holes in shutter frame. Shutter should be positioned so that louvers swing outward and upward. See Fig. 15. Check shutter to make sure it opens and closes freely. Also check to make sure there is clearance between shutter and fan blade.

STEP 5 — To mount this attic fan in gable or wall, a box must be framed into wall construction as shown in Fig. 16. Make opening in outside wall 37” x 37”.

STEP 6 — Insert frame containing fan and shutter assembly into opening with outside surface of shutter frame flush with outside surface of wall. See Fig. 16.

FIG. 8

SPRING ATTACHED

CONNECTOR

SPRING SHOWN

UNATTACHED

FIG. 9

FIG. 10

FIG. 11

SPRING HOLDER

LOCKING

SCREW

— 5 —

Page 5
Image 5
Marley Engineered Products A24DD manual Shutter Installation, WALL INSTALLATION MODEL 3130 SHUTTER, Fig. Fig. Fig