WIRING

STEP 6 — PRECAUTIONS: READ CAREFULLY BEFORE WIRING FAN!

A.Electrical connections and all wiring should be in accordance with the National Electrical Code and all local codes that may apply.

B.To avoid possibility of serious injury or electrical shock, the installer must disconnect electrical circuit supplying power prior to wiring fan.

C.CAUTION: Incorrect wiring can cause motor failure and possibly fire. Marley Engineered Products will not accept liability for damage resulting from incorrect wiring. Follow all wiring diagrams and instructions carefully!

D.This fan is designed to run on 120 volt A.C. 60 Hz power only.

STEP 7 — The 3-speed control packed with this fan is used to operate the fan from a remote wall location. Generally the best location is in the hallway near the fan. The control should be in sight of the fan. Install a single switch box at the location chosen.

STEP 8 — The wiring diagrams, Figs. 6 & 7, show two alternate methods of wiring fan control. If the 120V power supply is available at the fan, Fig. 6 should be followed. If the 120V power supply is available at the control, Fig. 7 should be followed. In either case, note that the brown control wire must be connected to the black (hot) wire from the 120 volt power supply

FIG. 6

FAN MOTOR OUTLET BOX

CONTROL OUTLET BOX

 

 

BLACK (HI)

BLACK (HI)

CONTROL

 

 

 

 

BLUE (MED)

BLUE (MED)

 

MOTOR

RED (LOW)

RED (LOW)

 

 

WHITE (COM)

 

 

 

BLACK

BROWN

 

120 V, 60 HZ

WHITE

 

 

 

 

 

GND. SCREW

120 V SUPPLY AVAILABLE AT FAN

FIG. 7

FAN MOTOR OUTLET BOX

CONTROL OUTLET BOX

 

BLACK (HI)

BLACK (HI)

CONTROL

 

 

 

 

BLUE (MED)

BLUE (MED)

 

MOTOR

RED (LOW)

RED (LOW)

 

 

 

 

WHITE (COM)

BROWN

 

 

 

BLACK

 

 

 

WHITE

120 V, 60 HZ

 

GND. SCREW

 

 

120 V SUPPLY AVAILABLE AT CONTROL

STEP 9 — After determining which diagram applies, pull wires to fan and control switch box. Be sure to secure cable at fan to prevent it from being caught in fan blade. Make connections to fan from room below, through hole cut in ceiling. After wiring of fan and control is completed and checked against the appropriate wiring diagram, replace outlet box cover on fan and secure control in switch box. Leave control in “OFF” position.

— 4 —

Page 4
Image 4
Marley Engineered Products A24DD manual Wiring, Supply Available AT FAN, Supply Available AT Control

A24DD specifications

Marley Engineered Products has long been recognized for its innovative solutions in the field of HVAC and fluid handling technologies. One of its outstanding offerings is the A24DD unit, a high-performance fan and heater combination designed to maximize efficiency and comfort in various applications.

The A24DD is strategically engineered with a focus on versatility. It is suitable for use in industrial, commercial, and residential settings, making it a popular choice among contractors and facility managers. Its compact design allows for easy installation in tight spaces, which is ideal for businesses that need to optimize their operational areas without compromising on heating solutions.

A key feature of the A24DD is its advanced airflow technology. The unit utilizes a direct drive motor, which not only enhances energy efficiency but also reduces noise levels, providing a quieter environment. This characteristic is particularly beneficial in settings where noise pollution can affect comfort or productivity, such as offices and schools.

The A24DD is equipped with a robust heating element that ensures rapid heat distribution, contributing to a warm and comfortable atmosphere in no time. The built-in safety features, including over-temperature protection and adjustable thermostat controls, enhance user safety and comfort. This system provides users the flexibility to adjust the temperature settings to meet their specific needs, ensuring efficient energy use.

In terms of durability, the A24DD stands out with its high-quality materials and construction. It is designed to withstand harsh conditions, making it an excellent option for various industrial applications. The corrosion-resistant housing ensures longevity, while the easy maintenance features reduce the total cost of ownership.

Another highlight of the A24DD is the integration of smart technologies. It can be linked with existing building management systems, allowing for streamlined operation and energy monitoring. This capability not only supports energy efficiency goals but also aids in maintaining the operational reliability of heating systems.

In summary, the Marley Engineered Products A24DD unit combines flexibility, efficiency, and advanced technology, making it a top choice for those seeking reliable heating solutions across a broad spectrum of environments. With its user-friendly features and commitment to safety and efficiency, the A24DD is redefining comfort and performance in heating systems.