CEILING INSTALLATION

LOCATING & MOUNTING FAN

STEP 1 — The A24DD fan mounts on ceiling joists that are spaced 16” O.C. Fan should be located in center of house, preferably in hallway or corridor. This will allow air to be drawn through all parts of living space. (See Fig. 1.) Determine tenta- tive location of fan and proceed as shown below.

STEP 2 — Determine joist direction and locate center joist in ten- tative fan opening. Lightly pencil a rectangular 30 1/2” x 33 1/2” opening on ceiling below where shutter is to be located. Make sure 33 1/2” side is parallel to joist direction. Check to be sure that enough clearance area is available on ceiling for overlap of shutter flanges (1 1/2” on all sides). Drill two small pilot holes close to center joist, (one on either side) to indicate where hole will be centered. (See Fig. 2.)

STEP 3 — Now clear insulation and find pilot holes in attic. Tentatively lay out same rectangular hole as on ceiling below. Adjust location of hole if necessary to insure a minimum verti- cal clearance from roof rafters of 18” above fan (Fig. 3).

FIG. 3

18” MIN

CLEARANCE

STEP 4 — Carefully cut hole in ceiling (Fig. 4), being careful not to cut into center joist. Cut along both sides of the center joist, leaving the 1 1/2” (approximately) strip of ceiling sheet rock cov- ering the center joist.

If you have 2 x 4 joist construction, the joists on which the fan will be mounted must be built up to 2 x 6 joist height. This can be done very easily at this point by nailing (3) 2 x 2 furring strips 38” long to the top of the joists, one on each joist.

STEP 5 — Remove adhesive backing from the 1/2” x 1/2” gas- ket material and attach to the bottom flanges of fan which rest on the joists. (Fig. 5) Now place fan on joists. Install grommet in bracket (Fig. 5) and attach on each end of fan, using two of the short screws provided. Position fan over opening so that grom- mets are resting against center joist. Attach fan and brackets to center joist with the two long wood screws and flat washers. Do not crush grommet when tightening screws.

FIG. 1

FIG. 2

OVERLAP AREA

PILOT HOLES

FIG. 4

EXISTING

2 X 6 JOISTS

(DO NOT CUT!)

FIG. 5

— 3 —

Page 3
Image 3
Marley Engineered Products A24DD manual Ceiling Installation, Locating & Mounting FAN

A24DD specifications

Marley Engineered Products has long been recognized for its innovative solutions in the field of HVAC and fluid handling technologies. One of its outstanding offerings is the A24DD unit, a high-performance fan and heater combination designed to maximize efficiency and comfort in various applications.

The A24DD is strategically engineered with a focus on versatility. It is suitable for use in industrial, commercial, and residential settings, making it a popular choice among contractors and facility managers. Its compact design allows for easy installation in tight spaces, which is ideal for businesses that need to optimize their operational areas without compromising on heating solutions.

A key feature of the A24DD is its advanced airflow technology. The unit utilizes a direct drive motor, which not only enhances energy efficiency but also reduces noise levels, providing a quieter environment. This characteristic is particularly beneficial in settings where noise pollution can affect comfort or productivity, such as offices and schools.

The A24DD is equipped with a robust heating element that ensures rapid heat distribution, contributing to a warm and comfortable atmosphere in no time. The built-in safety features, including over-temperature protection and adjustable thermostat controls, enhance user safety and comfort. This system provides users the flexibility to adjust the temperature settings to meet their specific needs, ensuring efficient energy use.

In terms of durability, the A24DD stands out with its high-quality materials and construction. It is designed to withstand harsh conditions, making it an excellent option for various industrial applications. The corrosion-resistant housing ensures longevity, while the easy maintenance features reduce the total cost of ownership.

Another highlight of the A24DD is the integration of smart technologies. It can be linked with existing building management systems, allowing for streamlined operation and energy monitoring. This capability not only supports energy efficiency goals but also aids in maintaining the operational reliability of heating systems.

In summary, the Marley Engineered Products A24DD unit combines flexibility, efficiency, and advanced technology, making it a top choice for those seeking reliable heating solutions across a broad spectrum of environments. With its user-friendly features and commitment to safety and efficiency, the A24DD is redefining comfort and performance in heating systems.