Marley Engineered Products E3609-1125HFD Troubleshooting Chart, Symptom, Possible Causes

Models: E4806-1125HFD E4212-1125HFD E4206-1125HFD E4209-1125HFD E3812-1125HFD E3806-1125HFD E4809-1125HFD E6012-2125HFD E6006-2125HFD E3606-1125HFD E4812-1125HFD E3612-1125HFD E6009-2125HFD E3809-1125HFD E3609-1125HFD

1 32
Download 32 pages 17.27 Kb
Page 5
Image 5

Troubleshooting Chart

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

 

 

 

 

Fan inoperative

1. Blown fuse or open circuit breaker.

1.

Replace fuse or reset circuit breaker.

 

2.

Electricity turned off.

2.

Contact local power company.

 

3.

Loose cord connection.

3.

Re-check all connections.

 

4.

Defective capacitor or motor.

4.

Replace.

 

 

 

 

Excessive noise

1. Wheel rubbing on housing.

1.

Center wheel.

 

2.

Motor base or blower not securely

2. Tighten mounting bolts.

 

 

anchored.

3.

Replace motor.

 

3.

Defective motor bearings.

 

 

 

 

 

 

Insufficient air flow

1. Improper voltage.

1.

Reconnect to proper voltage.

 

2.

Outlet louvers closed.

2.

Open.

 

3.

Intakes obstructed.

3.

Remove any obstruction.

 

4.

Motor speed setting on low.

4.

Position toggle switch to high.

 

5.

Dirty blower wheels

5.

Clean.

 

 

 

 

Too much air flow

1. Motor speed setting on high.

1.

Position toggle switch to low.

 

 

 

 

Fans cut out on

1. Low voltage.

1.

Verify correct wire size.

thermal overload

2. Obstruction to blower wheel.

2.

Remove obstruction.

(self-resets)

 

 

 

 

 

 

 

 

No heat

1. Fuse link open.

1.

Replace with 4K4204H or 4K9204H.

 

2.

Heater element broken.

2.

Replace with proper Ga. and watts.

 

3.

Control Transformer

3.

Replace with proper item.

 

 

 

 

 

5

Page 5
Image 5
Marley Engineered Products E3609-1125HFD, E6012-2125HFD Troubleshooting Chart, Symptom, Possible Causes, Corrective Action