E3606-1525HFD, E3609-1525HFD

Heated

Air Curtains

 

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

MODELS:

E3606-1525HFD, E3609-1525HFD

 

E3806-1525HFD, E3809-1525HFD

 

E4206-1525HFD, E4209-1525HFD

 

E4806-1525HFD, E4809-1525HFD

 

E6006-2525HFD, E6009-2525HFD

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

REFER TO INDIVIDUAL MODEL NUMBERS

FOR UNIT WIDTH

12

1

2

 

/

117/8

Figure 1

153/4

31/4E3806-1525HFD, E3809-1525HFD

Figure 2 Dimensions

Note that all dimensions are the same on all environmental series units. Model number indicates width of unit. (Example: E4800 indicates a 48” wide unit.)

Description

Air curtains produce a wall of continuously flowing air that acts as a thermal barrier against outside air and provides protection against insects, dust, odor, fumes and other contaminants. Maintains interior conditioned temperature by preventing heated or cooled air from escaping through open doorways.

Heated air curtains are engineered to treat incoming cold air at customers’ entrance areas. Used over front door entrances, heated air curtains supplement existing heat to prevent infiltration of colder outside air. Heated units are not recommended for areas subject to high winds.

Specifications and Performance

MODEL

HEATER

MOTOR

HEATER

HEATER

HEATER

CFM AT NOZZLE

MOTOR

NUMBER

VOLTAGE

VOLTAGE

WATTS

BTU/HR

AMPS

SIZE

(HI/LOW)

 

 

 

 

 

 

 

 

E3606-1525HFD

460/3

460/3

6000

20,478

7.5

2025

1/4HP

E3609-1525HFD

460/3

460/3

9000

30,717

11.4

2025

1/4HP

E4206-1525HFD

460/3

460/3

6000

20,478

7.5

2360

1/4HP

E4209-1525HFD

460/3

460/3

9000

30,717

11.4

2360

1/4HP

E4806-1525HFD

460/3

460/3

6000

20,478

7.5

2700

1/4HP

E4809-1525HFD

460/3

460/3

9000

30,717

11.4

2700

1/4HP

E6006-1525HFD

460/3

460/3

6000

20,478

7.5

3375

1/4HP

E6009-1525HFD

460/3

460/3

9000

30,717

11.4

3375

1/4HP

 

 

 

 

 

 

 

 

Note: For multiple unit installations, recommended spacing between units should be a minimum of 3-inches and a maximum of 6-inches. Unit is allowed to extend beyond doorway width. Each unit must have individual power supply.